Design specifications – Metrologic Instruments FocusBT MS1633 User Manual
Page 37
33
D
ESIGN
S
PECIFICATIONS
MS1633
D
ESIGN
S
PECIFICATIONS
O
PERATIONAL
Light Source: LED 645 nm
Pulse Duration: 10 µs to 8000 µs
Maximum Output: 0.76 mW Peak
Depth of Scan Field:
0 mm – 330 mm (0" – 13") for
0.330 mm (13 mil) Bar Code at Default Setting
49 mm W x 19 mm H (1.9" W x 0.8" H) at 20 mm (0.8")
Field of View:
264 mm x 106 mm (10.4" W x 4.2" H) at 280 mm (11.0")
Minimum Bar Width: 0.127 mm (5.0 mil)
Long Range: 0 mm – 203 mm (0" – 8") from Window
Infrared Activation:
Short Range: 0 mm – 101 mm (0" – 4") from Window
Motion Tolerance: 47 cm/sec (18"/sec) 100% UPC in stand
Decode Capability:
Autodiscriminates All Standard 1-D, GS1 Databar,
PDF417, microPDF, MaxiCode, Data Matrix, QR Code,
UCC, EAN Composites, Postals, Aztec
Image Transfer*:
BMP, TIFF, or JPEG output
*
RS232 and USB only
Print Contrast: 20% Minimum Reflectance Difference
Number Characters Read:
Up to 80 Data Characters on 1D;
1850 Text Characters for PDF417
Beeper Operation: 7 tones or no beep
Blue
Unit Powered, Ready to Scan
White Good
Read
Indicators (LED)
Default Settings:
Yellow In
Stand
Decoding and functional capability of the unit is restricted through the
use of license numbers provided by Metrologic. Units will not support
key features such as, but not limited to, the ability to decode PDF, 2D or
OCR fonts without the proper licenses. Desired licenses can be
specified at the time of sale or call a Metrologic representative for more
information. Standard models ship with the ability to read all 1D, PDF
and 2D bar codes. OCR fonts are disabled by default and must be
specifically requested at an additional cost.
Specifications are subject to change without notice.