beautypg.com

Nstallation place and electrical work, Pecifications, Installation place – MITSUBISHI ELECTRIC MR. SLIM MCF-D24VD User Manual

Page 9: Electrical work, When using the air conditioner again

background image

En-8

Installation place

Avoid installing the air conditioner in the following places.

• Where there is much machine oil.

• Salty places such as the seaside.

• Where sulfi de gas is generated such as a hot spring.

• Where oil is splashed or where the area is fi lled with oily smoke.

• Where there is high-frequency or wireless equipment.

• Where the air from the outdoor unit air outlet is blocked.

• Where the operation sound or air from the outdoor unit does not bother the

house next door.

Electrical work

• Provide an exclusive circuit for the power supply of the air conditioner.

• Be sure to observe the breaker capacity.

If you have any questions, consult your dealer.

I

NSTALLATION PLACE AND

ELECTRICAL WORK

S

PECIFICATIONS

To prevent the effects

of a fl uorescent lamp,

keep as far apart as

possible.

wall, etc.

Inverter-type
fl uorescent lamp

Keep a space to
prevent the pic-
ture distortion or
the noise.

1 m

or more

Radio

100 mm or
more

Well-
ventilated dry
place

200/500 mm
or more

TV

Cordless
phone or
Portable
phone

3 m or

more

1 m

or more

The installation location of the outdoor unit should

be at least 3 m away from the antennas for TV sets,

radios, etc. In areas where the reception is weak,

provide greater space between the outdoor unit and

the antenna of the affected device if operation of the air

conditioner interferes with radio or TV reception.

1

Set to the highest temperature in manual COOL mode,

and operate for 3 to 4 hours.

Page 4

This dries the inside of the unit.

2

Press

to stop the operation.

3

Turn off the breaker and/or disconnect the power sup-

ply plug.

4

Remove all batteries from the remote controller.

When using the air conditioner again:

1

Clean the air fi lter.

Page 6

2

Check that the air inlet and outlet of the indoor and

outdoor units are not blocked.

3

Check that the earth is connected correctly.

W

HEN THE AIR CONDITIONER IS NOT

GOING TO BE USED FOR A LONG TIME

Model

MCF-SD13VD

MCF-D18VD

MCF-D24VD

Dimensions

H × W × D (mm)

Indoor

650 Ч 1100 Ч 180

650 Ч 1100 Ч 180

650 Ч 1100 Ч 180

Outdoor

550 Ч 800 Ч 285

850 Ч 840 Ч 330

850 Ч 840 Ч 330

Weight (kg)

Indoor

26

26

26

Outdoor

34

54

65

Note:

1. Rating condition

Cooling — Indoor: 27°C DB, 19°C WB

Outdoor: 35°C DB, 24°C WB

2. Guaranteed operating range

Indoor

Outdoor

Upper limit

32°C DB

23°C WB

43°C DB

Lower limit

21°C DB

15°C WB

21°C DB

Environment care

Mitsubishi Electric Air conditioner has been designed environment-friendly. The plastic composition can be used as recycle part.

For the optimum effi ciency and energy saving, users are recommended to operate air conditioners as following suggestion.

Turn off air conditioner in case of not in use.

Turn off ventilator in case of not in use.

The set temperature should not be set lower than 25°C.

The cleaning of condensing coil should be performed at least every 3 months.

The cleaning of air cleaning fi lter should be performed in the period described in this manual.

SD13/D18, D24

This manual is related to the following products: