background image

En-4

I FEEL mode

The unit selects the operation mode according to the room temperature

when I FEEL is selected. When the room temperature is higher than 25°C,

COOL is selected (set temperature: 24°C). When the room temperature is

lower than 25°C, DRY is selected. However, when operation is stopped and

then started within 2 hours, the mode which has been selected previously

is operated.

Note:

During COOL operation, the set temperature may not be changed when

the room temperature is more than 2°C higher than the set temperature.

In this case, please wait until the room temperature drops to within 2°C of

the set temperature.

COOL mode

Enjoy cool air at your desired temperature.

DRY mode

Dehumidify your room. The room may be cooled slightly.

Temperature cannot be set during DRY mode.

FAN mode

Circulate the air in your room.

Operation indicator lamp

Operation indicator lamp

The operation indicator lamp shows the operation state of the unit.

Indication

Operation state

Room temperature

The unit is operating to reach the set

temperature

About 2°C or more away

from set temperature

The room temperature is approaching

the set temperature

About 1 to 2°C from set

temperature

Lighted

Not lighted

Emergency operation

When the remote controller cannot be used...

Emergency operation can be activated by pressing the emergency operation

switch (E.O.SW) on the indoor unit.

Each time the E.O.SW is pressed, the operation changes in

the following order:

1

Press

to start the operation.

2

Press

to select operation mode. Each press

changes mode in the following order:

3

Press or to set the temperature.

Each press raises or lowers the temperature by 1°C.

Press

to stop the operation.

• The same setting is selected the next time by simply pressing

.

Auto restart function

If a power failure occurs or the main power is turned off during operation, “Auto

restart function” automatically starts operation in the same mode as the one set

with the remote controller just before the shutoff of the main power. When

timer is set, timer setting is cancelled and the unit starts operation when power

is resumed.

If you do not want to use this function, please consult the service

representative because the setting of the unit needs to be changed.

S

ELECTING OPERATION MODES

Set temperature : 24°C

Fan speed : Medium

Horizontal vane : Auto

(I FEEL)

(COOL)

(DRY)

(FAN)

Emergency COOL

Stop

Note:

The fi rst 30 minutes of operation is test run. Temperature

control does not work, and fan speed is set to High.

I FEEL COOL

DRY

FAN

AMPM

AMPM

This manual is related to the following products: