Design specifications, Operational – Metrologic Instruments MS9500 Voyager User Manual
Page 37

31
D
ESIGN
S
PECIFICATIONS
MS9500 Series Specifications
O
PERATIONAL
Light Source
Visible Laser Diode 650 nm
Laser Power:
Less than 1 mW (peak)
Depth of Scan Field:
0 mm - 203 mm (0" - 8") for
0.330 mm (13 mil) bar code@ default setting
Scan Speed:
72 scan lines per second
Scan Pattern:
Single scan line
Minimum Bar Width:
0.127 mm (5.0 mil)
Infrared Activation:
Long Range: 0 mm – 279 mm ± 51 mm (0" – 11" ± 2")
Short Range: 0 mm – 102 mm ± 25 mm (0" – 4" ± 1")
Decode Capability
Autodiscriminates all standard bar codes for others call
a Metrologic service representative
System Interfaces
RS232, PC Keyboard Wedge, Stand-Alone Keyboard,
OCIA, IBM 468X/469X, Light Pen Emulation, Laser
Emulation, RS232 with DSR, Low Speed USB POS or
HID, Full Speed USB
Print Contrast:
35% minimum reflectance difference
Number Characters
Read:
Up to 80 data characters (Maximum number will vary
based on symbology & density)
Roll, Pitch, Yaw:
42°, 68°, 52°
Beeper Operation:
7 tones or no beep
Green* LED = laser on, ready to scan
Red* LED = good read
Visual Indicators:
Default Settings
Yellow LED (MS9540 Only) =
ON, CodeGate button is inactive
OFF, CodeGate button is active
*
In some custom units the standard green LED has been replaced with a blue LED
and the red LED has been replaced with a white LED.