VIII. GAS SUPPLY (gas ovens only)

A. Connection
NOTE:
It may be necessary to temporarily remove the rear cool

panels to connect the gas supply.
Check the oven’s gas supply requirements before making the

gas utility connection. Gas supply requirements are listed on

the oven’s serial plate (Figure 2-16) and in the Gas Orifice and

Pressure Specifications table (Page 4 of this manual).
Check the serial plate to determine the type of gas (Propane or

Natural) to be used with the oven.
Refer to the instructions in the gas hose package (included in

the Installation Kit) before connecting the gas line. One gas line

connection method is shown in Figure 2-18; however,

CAUTION

DURING PRESSURE TESTING NOTE ONE OF THE FOLLOW-

ING:
1. The oven and its individual shutoff valve must be

disconnected from the gas supply piping system during

any pressure testing of that system at test pressure in

excess of 1/2 psi (3.45 kPa).
2. The oven must be isolated from the gas supply piping

system by closing its individual manual shutoff valve

during any pressure testing of the gas supply piping

system at test pressure equal to or less than 1/2 psi (3.45

kPa).
3. If incoming pressure is over 14” W.C. (35mbar), a

separate regulator MUST be installed in the line BEFORE

the individual shutoff valve for the oven.
WARNING:
To prevent damage to the control valve

regulator during initial turn- on of gas, it is very important

to open the manual shutoff valve very slowly.
After the initial gas turn-on, the manual shutoff valve

must remain open except during pressure testing as

outlined in the above steps or when necessary during

service maintenance.

compliance with the applicable standards and regulations is

mandatory.
Inlet, regulated, and pilot gas pressure readings can be taken

using a “U” tube manometer at the tap locations shown in Figure

2-19.
One 90° elbow equals a 7’ (2.13m) length of pipe. The

recommended pipe sizes are larger than usually required to

eliminate any operation problems. It is much less expensive

to make the initial installment large enough to do the job rather

than redoing the job later.
NOTE: The installation must conform with local codes or in the

absence of local codes, with the National Fuel Gas Code, ANSI

Z223.1-latest edition.
In Australia, the installation must conform with AGA Code

AG601 and with any requirements of the appropriate statutory

authority.
CANADIAN:

CAN/CGA-B 149.1 Natural Gas Installation Code

CAN/CGA-B 149.2 Propane Installation Code
Certain safety code requirements exist for the installation of gas

ovens; refer to the beginning of Section 2 for a list of the

installation standards. In addition, because the oven is equipped

with casters, the gas line connection shall be made with a

connector that complies with the Standard for Connectors for

Movable Gas Appliances, ANSI Z21.69 (in U.S.A.), or, if appli-

cable, Connectors for Movable Gas Appliances, CAN/CGA-6.16

(in Canada), as well as a quick-disconnect device that complies

with the Standard for Quick-Disconnect Devices for Use With

Gas Fuel, ANSI Z21.41 (in U.S.A.), or, if applicable, Quick-

Disconnect Devices for Use With Gas Fuel, CAN1-6.9 (in

Canada).

B. Gas Conversion
Where permitted by local and national codes, it is possible to

convert ovens from natural to propane gas, or from propane to

natural gas. Use the appropriate Middleby Marshall Gas

Conversion Kit for the specific oven model.

WARNING

All installations, conversions and service work must be

performed by an authorized service agent.

Figure 2-19 - Gas Burner and Piping Assembly

Manual

shutoff valve

Pilot pressure tap

(where pilot gas

pressure is measured)

Combination Gas

Control Valve

(Safety Regulator)

Inlet pressure tap

(where incoming

gas pressure is

measured)

Manifold pressure tap

(where manifold gas

pressure is measured)

On/Off Knob

Always leave in

“ON” position

Low Flame

Bypass Line

High Flame

Solenoid Valve

Burner Blower

Gas Burner