Multitech V.90/K56FLEX MT5600ZDXV User Manual
Page 42

42
Models MT5600ZDX & ZDXV
Command: &Mn Communications Mode
Values:
n = 0
Defaults:
0
Description: &M0
Asynchronous mode.
&M1
Reservedresponds ERROR.
*&M0 selects direct asynchronous operation. Note that the command
sequence &M0\N0 selects normal buffered mode, but the command
sequence \N0&M0 selects direct mode. This is because the \N0 command
is analogous to the &Q6 command.
Command: &Qn Asynchronous Communications Mode
Values:
n = 0, 5, or 6
Defaults:
5
Description: &Q0
Asynchronous with no data buffering/no error
correction. Same as \N0.
&Q5
Asynchronous with data buffering/error correction.
Same as \N3.
&Q6
Asynchronous with data buffering/no error correc-
tion. Same as \N0.
Command: &Sn Data Set Ready (DSR) Control
Values:
n = 0 or 1
Default:
0
Description: &S0
Force DSR ON at all times.
&S1
DSR becomes active after answer tone is detected
(CD), and inactive after carrier tone is lost.
Command: $SBn Serial Baud Rate
(Modem DTE Speed; bps)
{ zdx only }
Values :
n = 300, 1200, 2400, 4800, 9600, 192000, 38400,
57600, 115200 (in bits per second)
Default:
56000
Description:
Example: $SB115200. Sets serial baud rate within a
host/server PC to 115,200 bps.
Command: &Tn
Test Commands
Values:
n = 0, 1, 3, 4, 5, 6, 7 or 8
Default:
None
Description: &T0
Abort. Stop any test in progress.
&T1