Dvd premium pro series microboards technology, llc – MicroBoards Technology Premium Pro User Manual
Page 20
DVD Premium Pro Series MICROBOARDS TECHNOLOGY, LLC
20
00
12
AUDIO PLAY OPERATION PAUSED
00
13
AUDIO PLAY OPERATION SUCCESSFULLY
00
14
AUDIO PLAY OPERATION STOPPED DUE TO ERRPOR
00
15
NO CURRENT AUDIO STATUS TO RETURN
02
00
NO SEEK COMPLETE
04
00
LOGICAL UNIT NOT READY, CAUSE NOT REPORTABLE
04
01
LOGICAL UNIT IS IN PROCESS OF BECOMING READY
04
02
LOGICAL UNIT NOT READY, INITIALIZING CMD. REQUIRED
04
03
LOGICAL UNIT NOT READY, MANUAL INTERVENTION REQUIRED
04
04
LOGICAL UNIT NOT READY, FORMAT IN PROGRESS
04
07
LOGICAL UNIT NOT READY, OPERATION IN PROGRESS
04
08
LOGICAL UNIT NOT READY, LONG WRITE IN PROGRESS
05
00
LOGICAL UNIT DOES NOT RESPOND TO SELECTION
06
00
NO REFERENCE POSITION FOUND
08
00
LOGICAL UNIT COMMUNICATION FAILURE
08
01
LOGICAL UNIT COMUUNICATION TIME-OUT
08
02
LOGICAL UNIT COMMUNICATION PARITY ERROR
08
03
LOGICAL UNIT COMMUNICATION CRC ERROR (ULTRA-DMA/32)
09
00
TRACK FOLLOWING ERROR
09
01
TRACKING SERVO FAILURE
09
02
FOCUS SERVO FAILURE
09
03
SPINDLE SERVO FAILURE
0A
00
ERROR LOG OVERFLOW
0B 00
WARNING
0B
01
WARNING-SPECIFIED TEMPERATURE EXCEEDED
0B 02
WARNING-ENCLOSURE
DEGRADED
0C 00
WRITE
ERROR
0C 02
WRITE
ERROR-RECOVERED
WITH AUTO REALLOCATION
0C
03
WRITE ERROR-RECOMMEND REASSIGNMENT
0C
07
WRITE ERROR-RECOVERY NEEDED
0C
08
WRITE ERROR-RECOVERY FAILED
0C
09
WRITE ERROR-LOSS OF STREAMING
0C 0A
WRITE
ERROR-PADDING BLOCKS ADDED
11
00
UNRECOVERED READ ERROR
11
06
CIRC UNRECOVERED ERROR
15
00
RANDOM POSITIONING ERROR
15
01
MECHANICAL POSITIONING ERROR
15
02
POSITIONING ERROR DETECTED BY READ OF MEDIUM
16
00
DATA SYNCHRONIZATION MARK ERROR
16
01
DATA SYNC ERROR-DATA REWRITTEN
16
02
DATA SYNC ERROR-RECOMMEND REWRITE
16
03
DATA SYNC ERROR-DATA ATUO-REALLOCATED
16
04
DATA SYNC ERROR-RECOMMEND REASSIGNMENT
17
00
RECOVERED DATA WITH NO ERROR CORRECTION APPLIED
17
01
RECOVERED DATA WITH RETRIES
17
02
RECOVERED DATA WITH POSITIVE HEAD OFFSET
17
03
RECOVERED DATA WITH NEGATIVE HEAD OFFSET
17
04
RECOVERED DATA WITH RETRIES AND/OR CIRC APPLIED
17
05
RECOVERED DATA USING PREVIOUS SECTOR ID
17 06
RECOVERED
DATA
WITHOUT
ECC - DATA AUTO-REALLOCATED
17 07
RECOVERED
DATA
WITHOUT
ECC - RECOMMEND REASSIGNMENT
17 08
RECOVERED
DATA
WITHOUT ECC - RECOMMEND REWRITE
17
09
RECOVERED DATA WITHOUT ECC - DATA REWRITTEN
18
00
RECOVERED DATA WITH ERROR CORRECTION APPLIED
18
01
RECOVERED DATA WITH ERROR CORR. & RETRIES APPLIED
18
02
RECOVERED DATA - DATA AUTO-REALLOCATED
18
03
RECOVERED DATA WITH CIRC
18
04
RECOVERED DATA WITH L-EC
18
05
RECOVERED DATA - RECOMMEND REASSIGNMENT
18
06
RECOVERED DATA - RECOMMEND REWRITE
18
07
RECOVERED DATA WITH ECC - DATA REWRITTEN
19
00
DEFECT LIST NOT ERROR
19
01
DEFECT LIST NOT AVAILABLE
19
02
DEFECT LIST ERROR IN PRIMARY LIST
19
03
DEFECT LIST ERROR IN GROWN LIST
1A
00
PARAMETER LIST LENGTH ERROR
1B
00
SYNCHRONOUS DATA TRANSFER ERROR
1C
00
DEFECT LIST NOT FOUND
1C
01
PRIMARY DEFECT LIST NOT FOUND
1C
02
GROWN DEFECT LIST NOT FOUND
1D 00
MISCOMPARE
DURING VERIFY OPERATION
20
00
INVALID COMMAND OPERATION CODE
21
00
LOGICAL BLOCK ADDRESS OUT OF RANGE
21
02
INVALID ADDRESS FOR WRITE
24
00
INVALID FIELD IN CDB
25
00
LOGICAL UNIT NOT SUPPORTED
26
00
INVALID FIELD IN PARAMETER LIST
26
01
PARAMETER NOT SUPPORTED
26 02
PARAMETER
VALUE INVALID