beautypg.com

Ga-6h/ga-6ha — maintenance (engine), Danger – Multiquip MQ Multiquip Portable Generators ga-6h User Manual

Page 31

background image

GA-6H/GA-6HA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (06/02/05) — PAGE 31

GA-6H/GA-6HA — MAINTENANCE (ENGINE)

Maintenance

Perform the scheduled maintenance procedures as defined by
Table 6 and below:

DAILY
■ Thoroughly remove dirt and oil from the engine and control

area. Clean or replace the air cleaner elements as necessary.
Check and retighten all fasteners as necessary. Check the
gearbox for oil leaks. Repair or replace as needed.

WEEKLY
■ Remove the fuel filter cap and clean the inside of the fuel

tank.

■ Remove or clean the filter at the bottom of the tank.
■ Remove and clean the spark plug (Figure 26), then adjust

the spark gap to 0.024 ~0.028 inch (0.6~0.7 mm). This unit
has electronic ignition, which requires no adjustments.

ENGINE OIL

1. Drain the engine oil when the oil is

warm

as shown in

Figure 27.

2. Remove the oil drain bolt and sealing washer and allow

the oil to drain into a suitable container.

3. Replace engine oil with recommended type oil as listed

in Table 5. For engine oil capacity, see Table 2 (engine
specifications). DO NOT overfill.

4. Install drain bolt with sealing washer and tighten se-

curely.

Figure 27. Engine Oil (Draining)

Figure 26. Spark Plug Gap

ENGINE AIR CLEANER

1. Remove the air cleaner cover and foam filter element as

shown in Figure 28.

2. Clean foam element in warm, soapy water or nonflammable

solvent. Rinse and dry thoroughly. Dip the element in clean
engine oil and completely squeeze out the excess oil from the
element before installing.

Figure 28. Engine Air Cleaner

DO NOT use gasoline as a cleaning solvent,
because that would create a risk of fire or
explosion.

DANGER

DANGER

DANGER

DANGER

DANGER