6. If the engine has started, slowly return the choke lever

(Figure 12 ) to the

“OPEN”

position. If the engine has not

started repeat steps 1 through 5.

7. Before the generators is placed into operation, run the

engine for 3-5 minutes. Check for abnormal smells, fuel
leaks, and noises that would associate with lose compo-
nents.

8.

Place the idle control switch (Figure 15) in the "OFF"
(down) position. This will allow the engine speed to run
at speed about 3600 RPM's

3. Read the

voltmeter on the front panel of the generators

(Figure 19) and verify that120 VAC is present at the
120V twist-lock and GFCI duplex receptacles. For
additional verification of voltage, an external voltmeter
can be used to measure the output voltage as shown in
Figure 19.

Figure 19. 120 V and GFCI Receptacles

NOTE

Placing the

idle control switch

in

the OFF position (Figure 15) allows
the engine to operate at a maximum
speed of about 3600 RPM's. When
the idle control switch is placed in
the up position (ON) (Figure 16),

the generators will run at idle speed (2200 RPM's) until a load is
applied, at that time the engine speed will increase to 3600
RPM's as long as the load is being applied. When the load is not
in use, the engine speed will drop back to the idle mode after
about 3 seconds.

GA-6H/GA-6HA — INITIAL START-UP/GENERATOR OPERATION

Figure 15. Idle Control Switch (Off)

Figure 16. Idle Control Switch (On)

Figure 17. Main Circuit Breaker (ON)

60 Hz Operation

1. Place main circuit breaker (Figure 17) in the ON position.

2. Place the full power switch (Figure 18) in the 120V

position (up).

When the

full power switch is in the 120 V

position, the 240V twist-lock receptacle

cannot be used.

NOTE

4. Place the full power switch (Figure 20) in the 240V

position (down).

Figure 18. Full Power Switch 120 V Position (Up)

Figure 20. Full Power Switch 240/120 V Position (Down)