Nstallation place and electrical work, Pecifications, Installation place – MITSUBISHI ELECTRIC MSZ-FD25VA User Manual

Page 11: Electrical work, When using the air conditioner again

background image

En-10

Installation place

Avoid installing the air conditioner in the following places.

• Where there is much machine oil.

• Salty places such as the seaside.

• Where sulfi de gas is generated such as a hot spring.

• Where oil is splashed or where the area is fi lled with oily smoke.

• Where there is high-frequency or wireless equipment.

• Where the air from the outdoor unit air outlet is blocked.

• Where the operation sound or air from the outdoor unit does not bother the

house next door.

Electrical work

• Provide an exclusive circuit for the power supply of the air conditioner.

• Be sure to observe the breaker capacity.

If you have any questions, consult your dealer.

Model

Indoor

MSZ-FD25VA

MSZ-FD25VA

MSZ-FD35VA

MSZ-FD35VA

Outdoor

MUZ-FD25VA

MUZ-FD25VAH

MUZ-FD35VA

MUZ-FD35VAH

Function

Cooling

Heating

Cooling

Heating

Cooling

Heating

Cooling

Heating

Power supply

~ /N, 230 V, 50 Hz

~ /N, 230 V, 50 Hz

Capacity

kW

2.5

3.2

2.5

3.2

3.5

4.0

3.5

4.0

Input

kW

0.485

0.610

0.485

0.610

0.850

0.865

0.835

0.850

Weight

Indoor

kg

12

12

Outdoor

kg

36

36

Refrigerant fi lling capacity (R410A)

kg

1.15

1.15

IP code

Indoor

IP 20

IP 20

Outdoor

IP 24

IP 24

Permissible excessive

operating pressure

LP ps

MPa

1.64

1.64

HP ps

MPa

4.15

4.15

Noise level

Indoor (Super High/

High/Med./Low)

dB(A) 42/36/29/20 43/36/29/20 42/36/29/20 43/36/29/20 43/36/29/21 44/36/29/21 43/36/29/21 44/36/29/21

Outdoor

dB(A)

46

47

50

47

50

Indoor

Outdoor

MUZ-FD25/35VA MUZ-FD25/35VAH

Cooling

Upper limit

32°C DB

23°C WB

46°C DB

46°C DB

Lower limit

21°C DB

15°C WB

-10°C DB

-10°C DB

Heating

Upper limit

27°C DB

24°C DB

18°C WB

24°C DB

18°C WB

Lower limit

20°C DB

-15°C DB

-16°C WB

-20°C DB

-21°C WB

Note:

Rating condition

Cooling — Indoor:

27°C DB, 19°C WB

Outdoor: 35°C DB

Heating — Indoor:

20°C DB

Outdoor: 7°C DB, 6°C WB

Guaranteed operating range

I

NSTALLATION PLACE AND

ELECTRICAL WORK

S

PECIFICATIONS

To prevent the effects

of a fl uorescent lamp,

keep as far apart as

possible.

wall, etc.

Inverter-type
fl uorescent lamp

Keep a space to
prevent the pic-
ture distortion or
the noise.

1 m

or more

Radio

100 mm or
more

Well-
ventilated dry
place

200 mm or
more

TV

Cordless
phone or
Portable
phone

3 m or

more

1 m

or more

The installation location of the outdoor unit should

be at least 3 m away from the antennas for TV sets,

radios, etc. In areas where the reception is weak,

provide greater space between the outdoor unit and

the antenna of the affected device if operation of the air

conditioner interferes with radio or TV reception.

1

Set to the highest temperature in manual COOL mode,

and operate for 3 to 4 hours.

Page 5

This dries the inside of the unit.

2

Press

to stop the operation.

3

Turn off the breaker and/or disconnect the power sup-

ply plug.

4

Remove all batteries from the remote controller.

When using the air conditioner again:

1

Clean the air fi lter.

Page 8

2

Check that the air inlet and outlet of the indoor and

outdoor units are not blocked.

3

Check that the earth is connected correctly.

W

HEN THE AIR CONDITIONER IS NOT

GOING TO BE USED FOR A LONG TIME