6

³

9

9

9

9

9

4

Load Keyboard

Wedge Defaults

Figure 2: Keyboard Wedge

Interface

I

NSTALLATION FOR

K

EYBOARD

W

EDGE

I

NTERFACE

1. Follow the “Getting Started” steps on

page 3.

2. Turn off the host system.

3. Disconnect the keyboard from the host.

4. Connect the PowerLink cable to the 10-pin

KBW interface jack. It is the 2

nd

round

opening from the left side of the MS7220 (see
figure 2
).

5. Connect the “Y” end of the PowerLink cable

to the keyboard and the keyboard port on the
host. If necessary use the male/female
adapter cable supplied with the scanner for
proper connections.

Before continuing verify that the PowerLink
cable is connected to the appropriate
interface jack on the scanner. An incorrect
cable connection can cause communication
problems or potential damage to the scanner.

6. Connect the external power supply to the

power jack on the PowerLink cable.

7. Check the AC input requirements of the

power supply to make sure the voltage
matches the AC outlet.

8. Connect AC power to the transformer. The

outlet should be near the equipment and
easily accessible.

9. Slide the cable cover into place on the back

of the scanner then secure it with the three
M3 screws provided.

10. Turn on the host system.

11. Scan the bar code below to configure the

MS7220 for Keyboard Wedge
communication.

Caution:

To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements
for SELV (Safety Extra Low Voltage) according to EN 60950.

To maintain compliance with standard CSA C22.2 No. 60950-00/UL 60950 and norm EN 60950, the power source
should meet applicable performance requirements for a limited power source.