beautypg.com

MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 9

background image

A - 8

(5) Auxiliary equipment and options

(a) The circuit protector used should be the EN or IEC Standard-compliant product of the model

described in Section 12.2.2.

(b) The sizes of the cables described in Section 12.2.2 meet the following requirements. To meet the

other requirements, follow Table 5 and Appendix C in EN60204.
y

Ambient temperature: 40 (104) [

°

C (

°

F)]

y

Sheath: PVC (polyvinyl chloride)

y

Installed on wall surface or open table tray

(6) Performing EMC tests

When EMC tests are run on a machine/device into which the servo amplifier has been installed, it must
conform to the electromagnetic compatibility (immunity/emission) standards after it has satisfied the
operating environment/electrical equipment specifications.
For the other EMC Directive guidelines on the servo amplifier, refer to the "EMC INSTALLATION
GUIDELINES".