beautypg.com

Summary of operation timings – Metrologic Instruments IS4921 User Manual

Page 34

background image

28

Summary of Operation Timings

Operation Timing Specifications

Parameter

Description

Typical

Relevant Note(s)

Tprw_up

Power Applied to Processor Ready Delay (USB)

6 seconds Notes 4 and 5

Tprw_up_ttl

Trigger or Wake Low to Processor Ready Delay (TTL) 5 seconds

Note 4

Tdec_idle

Trigger Low to Decode complete Delay

90 msec

Notes 1 and 2

Tdec_sleep

Trigger Low to Decode complete Delay

120 msec

Notes 1 and 3

Trig_min

Minimum Duration of Trigger Signal

20 msec

Trig_wake_min_pu

Minimum Activation Time for Trigger or
Wake Signal to Power Up TTL Unit

2 seconds

Notes:

1.

Timing is the same for Both TTL or USB version

2.

Processor is in Idle Mode when nTrig signal is received

3.

Processor is in Sleep Mode when nTrig signal is received

4.

Typical time specified may vary depending on the enumeration time of the USB host.

5.

Typical times specified are valid for an IS4920 or an IS4921 with a firmware version of 15848 or

higher. Units with a firmware version lower than 15848 may require up to 3 seconds of an additional
time.