Electrical work
• Provide an exclusive circuit for power supply of the air conditioner.
• Be sure to observe the breaker capacity.

Warning:

• The customer should not install this unit. If the unit is installed incorrectly, fire, electric shock, injury due to a falling unit, water leakage, etc.

may result.

• Do not connect using branched outlet or an extension cord, and do not attach many loads to one electric outlet.

A fire or electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.

Caution:

• Apply grounding

Do not connect a grounding wire to a gas pipe, water pipe, lightning rod or ground wire of a telephone.
If a grounding is incorrect, it may cause an electric shock.

• Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid place, etc.).

If the earth leakage breaker is not installed, it may cause an electric shock.

Inspection and maintenance
• When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
• Depending upon the conditions of use, an odor may be generated or dirt, dust, etc. may prevent proper drainage.
• It is recommended to apply inspection and maintenance (charged) by a specialist in addition to normal maintenance. Consult your dealer.

Also consider operation sound
• Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increase operating sound.
• If abnormal sound is heard during operation, consult your dealer.

Relocation
• When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.

Warning:

Repair or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer.

Disposal
• To dispose of this product, consult your dealer.

If you have any question, consult your dealer.

5. Installation, relocation and inspection

Model

Function
Power supply

Capacity

kW

BTU/h

Input

kW

Indoor unit
Airflow (Lo-Hi)

CMM

Noise level (Lo-Hi)

dB

Weight

kg

Outdoor unit
Noise level

dB

Refrigerant R410A

kg

Weight

kg

SLZ-A09AR

Cooling

Heating

2.5

3.0

8,500

10,200

0.76

0.87

SLZ-A09AR

8-10

32-38

16.5 + Grille 3

SUZ-A09VR

46

0.8

33

SLZ-A12AR

Cooling

Heating

~/N, 220-240V, 50Hz

3.2

3.8

10,900

12,900

1.06

1.07

SLZ-A12AR

9-11

34-39

16.5 + Grille 3

SUZ-A12VR

48

0.9

34

SLZ-A18AR

Cooling

Heating

4.3

4.8

14,600

16,300

1.53

1.50

SLZ-A18AR

9-11

35-40

16.5 + Grille 3

SUZ-A18VR

55

1.8

72

Notes: 1. Rating conditions (cooling) Indoor : 27°C DB, 19°C WB

Outdoor : 35°C DB

2. Rating conditions (heating) Indoor : 20°C DB

Outdoor : 7°C DB, 6°C WB

3. Specifications subject to change without notice.

Guaranteed operating range

Indoor

Outdoor

Cooling

Upper limit

32°C DB, 23°C WB

46°C DB, –

Lower limit

21°C DB, 15°C WB

-10°C DB, –

Heating

Upper limit

27°C DB

24°C DB, 18°C WB

Lower limit

20°C DB

-10°C DB, -11°C WB

Units should be installed by licensed electric contractor accordingly to local code requirement.