Indoor coil thermistor [RT12 (MAIN), RT13 (SUB)]
Room temperature thermistor (RT11)

Temperature (

:

)

Resistance (k

"

)

MSZ-FA25VA -

MSZ-FA35VA -

Indoor electronic control P.C. board

E1

E1

Release of Auto restart
function
Solder the Jumper wire
to JR07.
(Refer to 8-3.)

12V DC

Varistor
(NR11)

5V DC

Room temperature
thermistor (CN111)

Indoor coil thermistor
RT12(MAIN)

12

RT13(SUB)

34

(CN112)

Timer short mode
point JPG, JPS
(Refer to 8-1.)

Horizontal and
Vertical vane
motor(CN151)

}

9-7. Test point diagram and voltage

SW P.C. Board

Power monitor
receiver P.C.
board.

i-see Sensor
(CN110)

Fuse
(F11)

Front panel
driving motor
(CN1U1)

Safety device(Plasma unit)
(CN1T2)

Plasma deodorizing/air
purifying filter units
(CN1T1)

CN201

1

(Used for check of con-
ducting of thermal fuse)

Interlock switch(Fan)

(CN1R1)

6

(+)0V DC or 15V DC

5

(+)3-6V DC

4

15V DC

3

(-) Fiducial terminal of

cathode side on measur-
ing high-voltage DC

1

311V DC

Cement resistance

(R111)

Indoor fan motor
(CN211)

1

DC 2.5V during PLASMA
AIR PURIFYING/PLASMA

DEODORIZING operation

3

DC 12.5V during PLASMA
AIR PURIFYING/PLASMA

DEODORIZING operation

2

GND

CN1

High-voltage lead wire
(Red)

Standard lead wire
(Green)

Plasma power P.C. board

WASH reset
switch(SW2)

Emergency
operation
switch(SW1)

230V AC

Power supply input

{

OB371_--1qxp 05.1.17 12:50 Page 30