beautypg.com

Check of auto front panel – MITSUBISHI ELECTRIC MSZ-FA35VA User Manual

Page 28

background image

28

Check of auto front panel

H

Is the connector of the front panel
driving motor unit or the indoor
electric control P.C. board unplugged?

Front panel is normal.

Replace the front panel
driving motor unit.

Does the front panel automatically
open? (Does it start to move?)

Yes

Is the front panel held 10mm or
more upper than the level line of
the nozzle top?

Yes

No

Turn the remote controller ON.

Plug in the connector and
check from the start again.

Is the resistance value between
terminals of the front panel driving
motor unit normal?

Replace the indoor electric
control P.C. board.

Replace the front panel
driving motor unit.

No

No

Yes

Yes

No

Indoor unit and outdoor unit do not operate.

10 mm or
more

Z-Z side view

OB371_--1qxp 05.1.17 12:50 Page 28