Fig. 1 – Front panel of the ЭМ-1212-1 control module.


Functioning of the ЭМ-1212-1 control module as a part of the control system is

provided by microcontroller CS, PLIC, interface and buttons with LEDs. The microcontroller
(MC) together with the PLIC inquires the buttons. On request from the ЭМ-1209-1 controller
the MC forms a reply array with the codes of the buttons pressed and transfers it via the
RCLI channel to the ЭМ-1209-1 controller.

The MC of CS receives from the ЭМ-1209-1 controller a command array with

instructions for lighting up the LEDs and switches on the corresponding LEDs by means of
the PLIC. The working program of the ЭМ-1209-1 controller analyses the button state and
decides whether to light up the LEDs.

Correspondence between group numbers, channel numbers, TVD installation places

and the designation on the ТМ-1215-4 control module is shown in Table 2.

The ЭМ-1211 diagnostics module has a microprocessor and an interface receiving

arrays with data on the CS state from the ЭМ-1209-1 controller and provide visualization of
the data in video frames of the ACS.

The ЭМ-1204-1 videoswitch module contains a MC and an interface that receive

instructions from the ЭМ-1209-1 controller for commutation of video signals and control their
execution.

Table 2

Group-
channel

Place of TVD installation

Video signal

source

Designation on

ТМ-1215-4

1-1

Device

″Сигнал-3″

КТ-257

PERISCOPE

1-2

Fore end,

− 6 frame

ТМ-1220-1

FE

–6FR

1-3

1 room, 1 deck, starboard side

Неотон-08-2

1R 1D STB

1-4

1 room, 2 deck

Неотон-08-1

1R

2D

2-1

1 room, 1 deck, port side

Неотон-08-1

1R 1D PS

2-2

Superstructure, 20 frame

ТМ-1220-1

SUPRSTR 20FR

2-3

3 room, 1 deck

Неотон-08-2

3R

1D

2-4

3 room, 3 deck

Неотон-08

3R

3D

3-1

4 room, 1 deck

Неотон-08-2

4R

1D

3-2

BF, winch automated communication
system

ТМ-1220-1

WINCH

ACS

3-3

4 room, 2 deck, starboard

Неотон-08-1

4R 2D STB

3-4

4 room, 2 deck, port side

Неотон-08-1

4R 2D PS

4-1

5 room, port side

Неотон-08-2

5R

PS

4-2

5 room, starboard

Неотон-08-2

5R

STB

4-3

Pod, winch sonar system

ТМ-1220-1

WINCH

SS

4-4

4 room, 2 deck, PCS

Неотон-08

4R 2D PCS

5-1

6 room, 1 deck, aft

Неотон-08-1

6R 1D A

5-2

6 room, 1 deck, fore

Неотон-08-1

6R 1D F

5-3

Tiller

compartment

Неотон-08

TC

5-4

Pod, 108 frame

ТМ-1220-1

POD

108FR

ЭМ-1212-1

TROUBLE

GROUP

CHANNEL

TVD

CONTROL

TROUBLE

ЭМ-1204-1

ТМ-1304 N1

ЭМ-1205-1

ТМ-1304 N2

ЭМ-1209-1

ТМ-1304 N3

ЭМ-1242

ТМ-1304 N4

ЭМ-1213 N1

ТМ-1304 N5

ЭМ-1213 N2

ЭМ-1213 N3

ТМ-1215-4 N1

ТМ-1215-4 N2

ТМ-1215-4 N3

OFF


The ЭМ-1242 interface unit contains a MC and a PLIC that form an array with

chronometrical data on request from the ЭМ-1209-1 controller.

The ЭМ-1209-1 controller working program provides various priorities for the

ЭМ-1212-1 and ТМ-1215-4 control modules as per enabling and control of the TVDs. The
ЭМ-1212-1 control module has the highest control priority. The second comes the
ТМ-1215-4

No.1 control module, then - the ТМ-1215-4

No.2 control module and

ТМ-1215-4 No.3 control module.

The ЭМ-1209-1 prohibits accidental enabling the night channel of the KT-257

TV-camera in the day time. On the first press on button PERISCOPE NIGHT on any of the
ТМ-1215-4 control modules, the ЭМ-1209-1 controller will switch on the day channel of the

ТМ-1213

МТК-110МЭ

ДЕ-118-1

FUSE

1

2

3

4

5

NIGHT
MODE

1

TEST
ON

2

TVD

TO

CHECK

3

4

TVD
FROM CHECK

TEST ЭМ-1212-1

P. P.

14

13