beautypg.com

Microsoft TM--1104-3 User Manual

Page 10

background image

P. P.

Rev. P. Dokument

N

Signature

Data

ТЭ3.623.912-03РЭ

ТЭ3.623.912-03РЭ

Rev. P. Dokument

N

Signature Data

Size А3 /А4

Signature

and

Data

Invent N o

f dou

bl

Subst. of inv

ent

N

Signature

and

Data

Invent N o

f orig

.



































Fig.4 –ACS Frame No.2 "STATE OF МТК-110МЭ TVDs".


The "ON" column contains the numbers of the CPs, from which the TVDs were

switched on. If the same TVD was switched on from several CPs, their numbers are
displayed via blanks. The device including the ЭМ-1212-1 control module and the ВС-2 TVM
is designated as CP No.4 of the TV-complex. The "CTRL" column shows the number of a CP
of the TV-complex and the remote control command being executed from this CP.

The "CHECK" column shows the number of CP of the TV-complex from which the

TVD was chosen for servicing.

The number of ACS frame No.2 is shown in the right lower corner.
The ACS frame No.3, "MODULE FEEDING VOLTAGES" is shown in Fig.5.































Fig. 5 – ACS Frame No.3 "MODULE FEEDING VOLTAGES".


The feeding voltages are symbolically shown as horizontal lines with four marks. The

leftmost mark represents the zero point. The next three marks represent the minimum,
nominal and maximum values of the voltage. The length of a line denotes the voltage in a
non-linear scale. The position of the minimum mark corresponds to 95% of the rated voltage.
The position of the rightmost mark corresponds to 105% of the rated voltage. If the voltage
controlled falls out of the tolerance limits, the line blinks that is a sign of a fault in the module.
The output voltages of the three ЭМ-1213 power supply units are displayed in the upper part
of the frame. The supply voltages produced by power supply cells in the corresponding
modules are displayed below. The number of ACS frame No.3 is shown in the right lower
corner.

Frames are switched over by pressing the arrow buttons on the front panel of the

ЭМ-1211 diagnostics module (Fig.2).

The ЭМ-1212-1 control module indicates faulty modules of the TV-complex with the

LEDs, in accordance with the information received from the ЭМ-1211 diagnostics module via
the RCLI channel. Light-up of the LED of the МТК-110МЭ indicates a fault in some unit or
module not represented on the ЭМ-1212-1 control module front panel. To get more specific
information about the faulty module, the ACS frame No.1 should be output on the TVM
screen.

19

20

N

NAME

CODE

ON

CTRL

CHECK

1-1
1-2

1-3

PERISKOPE

FE-6FR

1R 1D STB

КТ-257

ТМ–1220-1

НЕОТОН-08-2

1

2 3

----

1 DAY

2 TEST

---

---

---

1

1-4

2-1

2-2

2-3

1R 2D

1R 1D PS

SUPRSTR 20FR

3R 1D

НЕОТОН-08-1

НЕОТОН-08-1

ТМ–1220-1

НЕОТОН-08-2

4

----

----

----

---

---

---

---

---

---

---

---

2-4

3-1

3-2

3R 3D

4R 1D

WINCH ACS

НЕОТОН-08

НЕОТОН-08-2

ТМ–1220-1

----
----

----

---

---

---

---

---

---

3-3

3-4

4-1

4-2

4R 2D STB

4R 2D PS

5R PS

5R STB

НЕОТОН-08-1
НЕОТОН-08-1

НЕОТОН-08-2

НЕОТОН-08-2

----
----

----

----

---

---

---

---

---

---

---

---

4-3

4-4

5-1

WINCH SS

4R 2D PCS

6R 1D A

ТМ–1220-1
НЕОТОН-08

НЕОТОН-08-1

----
----

----

---

---

---

---

---

---

5-2

5-3

5-4

6R 1D F

TC

POD 108FR

НЕОТОН-08-1

НЕОТОН-08
ТМ–1220-1

----
----

----

---

---

---

---

---

---

STATE OF МТК–110МЭ TVDs

N2

+6V1
+6V2

+6V3
-6V1

+27V1

+27V2

+5V

-5V

ЭМ–1204-1

+5V

ЭМ–1205-1

+5V

ЭМ–1209-1

+5V

ЭМ–1242

N1

ЭМ-1213

MODULE FEEDING VOLTAGES

N3

N2

N3