2 OPERATION

2.1 Operating Conditions and Safety Rules



The maximum permissible ratings of the device are shown in Table 4. Operation under

stresses beyond these maximum limits is unsafe and can cause permanent damage to the
device.
Table 4

Technical Parameter

Maximum Limit

Note

Primary side supply voltage

231 V, continuous

249 V, transient, up to 3 s

2.1.1 The device should be operated only by qualified personnel acquainted with this

OM, electric connection diagram ТЭ3.623.912-03Э4 and knowing the operating principle of
the device.

2.1.2 The device is fed with a dangerous for life voltage of 220 V. Therefore the

following safety rules must be observed:

- do not use the device without reliable grounding;
- do not use the device with its side or rear covers removed;
- do not use self-made fuses or those with ratings different from the recommended;
- never replace fuses or modules, connect or disconnect any cables when the device

is on.

2.1.3. No mechanical works should be done while the device is switched on.

2.2 Device Preparation for Operation


2.2.1 Safety Precautions during Installation



When preparing the device for operation make sure that:
- bonding point "

⊥" is connected to the hull of the object;

- all the modules are installed and fastened in their dedicated positions;
- all the fuses are installed and fixed in the holders.
During operation, bright rays of light from external sources of light should not fall onto

the screen of the BC-2 TVM.

2.2.2 External Examination of Device



Check connection of external cables to the device.

2.2.3 Initial Position of Controls before Use of Device


Prior to the device switch-on the POWER toggle switch under the drop cover of the

assembly unit should be in the off position. To open the drop cover unscrew the captive
screws.


2.2.4 Interconnection wit other Devices



The device is used together with device "Гном-2МЭ" that is not a part of the TV-

complex.

The device receives chronometrical information from "Гном-2МЭ" device via a line

with transformer decoupling. No reply information is transmitted to the "Гном-2МЭ" device.
The device state does not influence on operation of "Гном-2МЭ".

The device is the central module of the TV-complex and interacts directly or non-

directly with all the modules of the TV-complex.


2.2.5 Switching-On and Testing of Device



2.2.5.1 Make sure that the POWER switch on the ЩР-03 switchboard and also the

МТК-110МЭ, PANELS and PERISCOPE switches are turned on. The indicators of phase
voltage presence should light, phase voltages should be from 180 to 231 V.

2.2.5.2 Open the drop cover of the assembly unit.
Open the door of the device by rotating counter-clockwise the clamping nuts of the

locks and putting the handles of the locks into the "UNLK" position.

2.2.5.3 Switch on the POWER toggle switch under the drop cover of the assembly

unit. The following indicators should light up:

- presence of phase voltages, "P1", "P2", "P3"; this indicators are mounted on the front

panel of the assembly unit;

- "27V" on the front panel of the ВС-2 TVM;
- 16 indicators on the fuse panel of the fifth floor of the device;
- two indicators on еach of the front panels of the three ЭМ-1213 power supply units.
2.2.5.4 Turn on the

ВС-2 TVM by pressing the ON button. After this the indicator near

the ON button should light up.

Adjust brightness and contrast with the buttons on the TVM front panel as described in

item 1.2.1.3. of the present OM if necessary.

2.2.5.5 Press the button TEST ЭМ-1212-1 on the ЭМ-1212-1 control module. After

that:

- by turns, from top to bottom and from left to right, the red LEDs under the TROUBLE

inscription will light up and then go out;

P. P.

30

29