beautypg.com

Caution – Multiquip A.C. Generator Used with MLT Series Modular Light Towers KD6 User Manual

Page 24

background image

PAGE 24 —KD1800/KD6 A.C. GENERATOR— PARTS & OPERATION MANUAL — REV. #1 (06/16/05)

KD1800/KD6 — LOAD APPLICATION

Single Phase Load

Always be sure to check the nameplate on the generator
and equipment to insure the wattage, amperage and
frequency requirements are satisfactorily supplied by the
generator for operating the equipment.

Generally, the wattage listed on the nameplate of the
equipment is its rated output. Equipment may require 130—
150% more wattage than the rating on the nameplate, as
the wattage is influenced by the efficiency, power factor and
starting system of the equipment.

CAUTION:

Motors and motor-driven equipment draw
much greater current for starting than
during operation.

An inadequate size connecting cable which cannot carry
the required load can cause a voltage drop which can burn
out the appliance or tool and overheat the cable.

CAUTION:

Before connecting this generator to any
building’s electrical system, a licensed
electrician must install an isolation
(transfer) switch. Serious injury or death
may result without this transfer switch.

NOTE

If wattage is not given on the
equipment's name plate, approximate
wattage may be determined by
multiplying nameplate voltage by the
nameplate amperage.

WATTS = VOLTAGE x AMPERAGE

The power factor of this generator is 1.0. See Table 5 below
when connecting loads.

d

a

o

L

y

B

r

o

t

c

a

F

r

e

w

o

P

.

5

e

l

b

a

T

d

a

o

L

f

O

e

p

y

T

r

o

t

c

a

F

r

e

w

o

P

s

r

o

t

o

m

n

o

it

c

u

d

n

i

e

s

a

h

p

-

e

l

g

n

i

S

5

7

.

0

-

4

.

0

t

n

e

c

s

e

d

n

a

c

n

i

,

s

r

e

t

a

e

h

c

i

r

t

c

e

l

E

s

p

m

a

l

0

.

1

s

p

m

a

l

y

r

u

c

e

m

,

s

p

m

a

l

t

n

e

c

s

e

r

o

u

l

F

9

.

0

-

4

.

0

n

o

it

a

c

i

n

u

m

m

o

c

,

s

e

c

i

v

e

d

c

i

n

o

r

t

c

e

l

E

t

n

e

m

p

i

u

q

e

0

.

1

z When connecting ordinary power tools, a capacity of

up to the generating set’s rated output (kW) multiplied
by 0.8 can be used.

z When connecting a resistance load such as an

incandescent lamp or electric heater, a capacity of up
to the generating set’s rated output (kW) can be used.

z When connecting a fluorescent or mercury lamp, a

capacity of up to the generating set’s rated output (kW)
multiplied by 0.6 can be used.

z When connecting an electric drill or other power tools,

pay close attention to the required starting current
capacity.

This manual is related to the following products: