beautypg.com

Autostar #497 handbo x, Maintenance, Index – Meade Instruments LT SC Series User Manual

Page 41

background image

INDEX

AutoStar #497 HANDBO

X

41

7. If the LT Series is not to be used for an extended

period, perhaps for one month or more, it is

advisable to remove the batteries from the

telescope. Batteries left in the telescope for

prolonged periods may leak, causing damage to

the telescope’s electronic circuitry.

8. Do not leave the LT Series inside a sealed car on

a warm summer day; excessive ambient

temperatures can damage the telescope’s

internal lubrication and electronic circuitry.

Collimation

The optical collimation (alignment) of any astronomical

telescope used for serious purposes is important, but

in the case of the Schmidt-Cassegrain design of the

LT Series, such collimation is absolutely essential

for good performance. Take special care to read and

understand this section well so that your LT Series will

give you the best optical performance.

As part of fi nal optical testing, every Meade LT Series

is precisely collimated at the Meade factory before

shipment. However, vibrations in shipping can cause

the optical system to become misaligned. Re-aligning

the optics is, however, a straightforward process.

To check the collimation of your LT Series, center

a bright star that is overhead, or use a “hot spot” of

refl ected Sunlight from a chrome car bumper, with

the supplied 26mm eyepiece. Allow the telescope

to adjust to the temperature of your observation site

before proceeding; temperature differences between

the optics and the outside air can cause distortion in

the images.

With the star or hot spot centered, de-focus

the image.

You will notice that the out of focus star image looks

like a ring of light surrounding a dark central spot; the

The LT Series is a precision optical instrument designed

to yield a lifetime of rewarding viewing.

Given the care and respect due any precision

instrument, the LT Series will rarely, if ever, require

factory servicing. Maintenance guidelines include:

1. Avoid cleaning the telescope’s optics: a little dust

on the front surface of the telescope’s correcting

lens causes virtually no degradation of image

quality and should not be considered reason to

clean the lens.

2. When absolutely necessary, dust on the front lens

should be removed with gentle strokes of a camel

hair brush or blown off with an ear syringe

(available at any pharmacy). DO NOT use a

commercial photographic lens cleaner.

3. Organic materials (e.g., fi ngerprints) on the front

lens may be removed with a solution of 3 parts

distilled water to 1 part isopropyl alcohol. You

may also add 1 drop of biodegradable

dishwashing soap per pint of solution. Use soft,

white facial tissues and make short, gentle

strokes. Change tissues often.

4. CAUTION: Do not use scented or lotioned tissues

that can damage the optics.

5. Do not, for any reason, remove the correcting

plate from its machined housing for cleaning

or other purposes. You will almost certainly

not be able to replace the corrector in its proper

rotational orientation and serious degradation

of optical performance will result. Meade

Instruments assumes no liability for damage

incurred to the telescope in this way.

6. If the LT Series is used outdoors on a humid

night, water condensation on the telescope

surfaces will probably result. While such

condensation does not normally cause any

damage to the telescope, it is recommended that

the entire telescope be wiped down with a dry

cloth before the telescope is packed away. Do

not, however, wipe any of the optical surfaces.

Rather, simply allow the telescope to sit for some

time in the warm indoor air, so that the wet optical

surfaces can dry unattended.

MAINTENANCE

(1)

(2)

(3)

Figure 13: Collimation

MAINTENANCE

41

This manual is related to the following products: