beautypg.com

Caution, Warning – Middleby Marshall PS540 User Manual

Page 21

background image

SECTION 2

INSTALLATION

17

WARNING

DO NOT USE CONDUIT OR GAS LINE
FOR GROUND CONNECTION.

CAUTION

IT IS REQUIRED THAT THE OVEN BE
PLACED UNDER A VENTILATION
HOOD FOR ADEQUATE AIR SUPPLY
AND VENTILATION.

ELECTRIC AND GAS SUPPLY TO BE

PROVIDED BY CUSTOMER

ELECTRICAL SAFETY SWITCH

15 Amp circuit breaker / fused disconnect switch with
lockout/tagout electrical shutoff
for each oven. Wire
each oven separately.

ELECTRICAL SPECIFICATIONS

DOMESTIC or EXPORT: 208-240V blower motor,
1 phase, 4.1 Amp draw, 50/60 Hz, 208-240V control
circuit, 2 poles, 3-wire system per oven (2 hot, 1 grd).

Do

NOT use conduit for ground.

GAS RATING

Model PS540 is 110,000 BTU/hour, 116.0 mJ/h (27,720 kcal),
32.2 kW/hr.

MINIMUM GAS METER RATING

450 ft

3

/hour (12.6m

3

/h) for 1 or 2 ovens;

Add 180 cu. ft./hr (5.1 m

3

/h) for each additional oven.

Minimum rating does

not take other gas appliances into

consideration. Gas consumption varies at each site. Total
BTU/hr (kcal/hr) must be calculated during high flame
operation for each appliance to determine if the meter
needs to be larger.

MINIMUM GAS PIPE SIZE

Natural: 2

″ (51mm) ID for 1, 2, or 3 ovens with runs up

to 200 ft. (61m).
Must be a dedicated line.

Runs over 200 ft, (61m) consult factory.

Propane: 2

″ (51mm) ID for 1, 2, or 3 ovens with runs up

to 200 ft. (61m).
Must be a dedicated line.

Runs over 200 ft, (61m) consult factory.

UTILITY ROUGH-IN DIMENSIONS AND POSITIONING

FOR PS540-SERIES OVENS

GAS SAFETY VALVE

A 3/4

″ (19mm) ID (inner diameter) full-flow, gas shutoff

valve. A separate connection and valve must be provided
for each oven, as shown in Figure 2-9.

REQUIRED GAS SUPPLY PRESSURE

Natural: 6

″ to 12″ water column (13.8 to 29.9 mbar)

Propane: 11.5

″ to 12″ water column (28.7 to 29.9 mbar)

SUGGESTED

If space permits, electric and gas service should be
located near the control console end of the oven(s) to allow
convenient access to safety switches and valves.

USER SUPPLIED ITEMS (Figure 2-9)

I

TEM

D

ESCRIPTION

1

2

″ (51mm) × 2″ (51mm) × 3/4″ (19mm) TEE

2

3/4

″ (19mm) × 3″ (76mm) NIPPLE

3

3/4

″ (19mm) FULL FLOW GAS SHUTOFF VALVE

4

2

″ (51mm) × 3/4″ (19mm) 90° REDUCER ELBOW

5

2

″ (51mm) ID GAS SUPPLY PIPE LINE - NATURAL GAS

6

15 AMP TOGGLE SWITCH - 2 POLE for GAS

Figure 2-9. Typical PS540-Series Oven(s)

Installation

24"

610mm

6

ON

OFF

13-1/2"

343mm

2

3

2

6

ON

OFF

24"

610mm

2

3

2

27"

686mm

4

5

1

Suggested dimensions are shown; utility code
requirements supersede any factors shown.