Multimodemii user guide – Multi-Tech Systems MT5600BL User Manual
Page 98

MultiModemII User Guide
90
Receiver Sensitivity
-43 dBm under worst-case conditions
AGC Dynamic Range
43 dB
Interface
TIA/EIA RS-232C/ITU-T V.24/V.28
Connectors
DB25F RS-232C connector; two RJ-11 phone jacks (BA mod-
el) or three RJ-11 phone jacks (BL model); power connector
Cables
One 14-foot RJ-11 phone cable (USA); country-specific cord
for UK and International models; external power transformer
and cord
Note:
Any cables connected to the computer should be
shielded to reduce interference.
Diagnostics
Power-on self test, local analog loop, local digital loop, re-
mote digital loop
Indicators
32-character backlit LCD for status and configuration infor-
mation; LEDs for Transmit Data, Receive Data, Carrier De-
tect, Off Hook, Terminal Ready, and Test Mode
Speaker
1-inch speaker for call progress monitoring
Manual Controls
Power switch, speaker volume control, four LCD control
buttons
Environmental
Temperature range 0°–50°C (32°–120°F); humidity range
20–90% (non-condensing)
Power Requirement
120 VAC, 60 Hz, 16 W; 230V/50 Hz optional (international)
Power Consumption
12 W @ 0.1 A
Dimensions
15.8 cm wide × 22.9 cm long × 3.6 cm high (6.2" Ч 9.0" Ч 1.4")
Weight
0.9 kg (2 lb.)
Limited Warranty
10 years