beautypg.com

Irq setting, Initial inspection, Irq setting -5 – Moxa Technologies CA-132/132I User Manual

Page 13: Initial inspection -5

background image

Hardware Installation

CA-132/132I User’s

Manual 2-5

At this point, the start of I/O addresses of Port 2 will be automatically configured at 188.

A3

A4 A5 A6 A7

A8 A9

8

1 2 4 8

1 2

Hex

On

On

On

On

On

On

On

0×000

On

On On On On

On Off 0×200

On

On On On On

Off Off 0×300

On

On On On Off

Off Off 0×380

On

On On Off Off

Off Off

0×3C0

On

On Off Off Off

Off Off

0×3E0

On

Off Off Off Off

Off On 0×3F0

Off

Off Off Off Off

Off Off 0×3F8

Off

On On On On

On On 0×008

Off

Off On On On

On On 0×018

Off

Off Off On On

On On 0×038

Off

Off Off Off On

On On 0×078

Off

Off Off Off Off

On On 0×0F8

Off

Off Off Off Off

Off On 0×2F8


IRQ Setting

CA-132/132I Series has a jumper selectable function for you to configure IRQ settings. Before you
insert a CA-132/132I board into the PC/104 interface, you need to choose an available jumper from 3,
4, 5, 6, 7, 9, 10, 11, 12, or 15 to configure the IRQ setting.

Initial Inspection

Before we ship CA-132/132I products, we first perform a careful mechanical and electrical inspection
of these serial boards. Products should be free of any marks or scratches and in perfect electrical order
when customers receive them. Handle these boards only by their edges, since the static charge from
your body may damage the integrated circuits. Always keep the boards in their anti-static package
whenever they are not installed. You can also use this package to return the board should it need to be
repaired.