6.
Is Data Transfer Failing?
YES
•
Verify the local copper connection by starting a local copper loop-
back (set the loop-back switch on the local media converter to “CL”)
and then use a bit error test unit at the local location to run a bit error
test.
•
Verify the local fiber connection by starting a local fiber loop-back at
the remote location (set the loop-back switch on the remote media
converter to “FL”) and then use a bit error test unit at the local
location to run a bit error test.
•
Verify the remote copper connection by starting a local copper loop-
back at the remote location (set the loop-back switch on the remote
media converter to “CL”) and then use a bit error test unit at the
remote location to run a bit error test.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
•
Proceed to step 7.
[email protected] -- Click the “Transition Now” link for a live Web chat.
11
Declaration of Conformity
Name of Mfg:
Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
Model:
CCSCF30xx-10x Series Media Converter
Part Number:
CCSCF3011-100, CCSCF3013-100, CCSCF3014-100,
CCSCF3015-100, CCSCF3016-100, CCSCF3017-100,
CCSCF3018-100, CCSCF3019-100, CCSCF3029-100,
CCSCF3029-101, CCSCF3029-102, CCSCF3029-103,
CCSCF3039-100
Regulation:
EMC Directive 89/336/EEC
Purpose: To declare that the CCSCF30xx-10x to which this declaration refers is
in conformity with the following standards.
CISPR 22:1993; EN 55022:1998 Class A; EN 55024:1998; FCC Part 15 Subpart B;
61000-3-2:1995+A14:2000; 61000-3-3:1995; CFR 21 subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
September 19, 2005
Stephen Anderson, Vice-President of Engineering
Date
7.
Is the SDC (Signal Detect / Coax) LED illuminated yellow?
YES
•
A failure of the remote unit connected to the coax interface has
caused an Alarm Indication Signal (AIS) on the coax interface.
Correct the remote unit failure.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
•
Proceed to step 8.
8.
Is the SDF (Signal Detect / Fiber) LED illuminated yellow?
YES
•
A broken coax link has caused an Alarm Indication Signal (AIS) on
the fiber interface. Correct the coax link failure.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
Fiber
Coax
Coax
Original Fault
AIS on the coax link
Fiber
Coax
Coax
Original
Fault
AIS on the fiber link