Cable specifications -- continued, Technical specifications, Troubleshooting – Milan Technology CCSF30XX-100 User Manual
Page 5
8
CCSCF30xx-10x
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Cable Specifications -- Continued
CCSCF3039-100
1300 nm multimode
Fiber-optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber-optic Receiver Sensitivity:
min: -30.0 dBm
max: -14.0 dBm
Link Budget:
11.0 dB
The fiber optic transmitters on this device meet Class I Laser safety requirements
per IEC-825/CDRH standards and comply with 21 CFR1040.10 and
21CFR1040.11.
Technical Specifications
For use with Transition Networks Model CCSCF30xx-10x or equivalent
Standards
FCC Class A; EN 55022 Class A; EN 55024; ANSI
T1.102-1993; ETSI TBR-24; ITU-T G.703 G.823 for
jitter tolerance; G.775 for loss of signal; Telecordia
GR-499CORE & GR-253-CORE
Data Rate
DS3 / T3 = 44.7 Mb/s
E3 = 34.4 Mb/s
Dimensions
3.4" x 5" x 0.87" (86 mm x 182 mm x 22 mm)
Weight
3 oz. (91 g) (approximately)
Power Consumption
6.0 Watts
MTBF
478,000 (MIL217F2 V5.0) (MIL-HDBD-217F)
1,333,000 (Bellcore7 V5.0)
Environment
Tmra*:
0 to 60°C (32° to 140°F )
Storage Temp:
-20° to 85°C (-4° to 185°F)
Humidity:
5 to 95%, non condensing
Altitude:
0 to 10,000 feet
Warranty
Lifetime
*Manufacturer’s rated ambient temperature: Tmra range for this slide-in-module
depends on the physical characteristics and the installation configuration of the
Transition Networks PointSystem™ chassis in which this slide-in-module will be
installed.
The information in this user’s guide is subject to change. For the most up-to-date
information on the CCSCF30xx-10x media converter, view the user’s guide on-
line at: www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not stare into
the beam or view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
[email protected] -- Click the “Transition Now” link for a live Web chat.
9
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:
1.
Is the PWR (Power) LED illuminated?
NO
•
Ensure the media converter slide-in-module is installed properly in
the chassis.
•
Ensure the power cord is properly installed in the chassis and at the
external power source.
•
Ensure the external power source provides power.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 2.
2.
Is the SDC (Signal Detect / Coax) LED illuminated green?
NO
•
Check the coax cables for the proper connection.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 3.
3.
Is the SDF (Signal Detect / Fiber) LED illuminated green?
NO
•
Check the fiber cables for proper connection.
•
Verify that the TX and RX cables on the local media converter are
connected to the RX and TX ports, respectively, on the remote media
converter.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 4.
4.
Is the SDC (Signal Detect / Coax) LED flashing green?
YES
•
The coax link is in loop-back mode. For normal operation, set the
loop-back switch to the center (normal) position.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
•
Proceed to step 5.
5.
Is the SDF (Signal Detect / Fiber) LED flashing green?
YES
•
The fiber link is in loop-back mode. For normal operation, set the
loop-back switch to the center (normal) position.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
•
Proceed to step 6.