Operation, Installation, Cable specifications – Milan Technology CCSF30XX-100 User Manual
Page 4: Snmp, Continued power the media converter, Coax cable, Fiber cable
CCSCF30xx-11x
6
Operation
After installation, the media converter should function without
operator intervention. Use the status LEDs to monitor the media
converter operation in the network.
SDC
Green on
The coax link is up.
Green flashing
The coax link is in loop-back mode.
Yellow on
AIS (Alarm Indication Signal) on the
coax link.
SDF
Green on
The fiber link is up.
Green flashing
The fiber link is in loop-back mode.
Yellow on
AIS (Alarm Indication Signal) on the
fiber link.
PWR Green on
The media converter is connected to
external power.
SNMP
See the on-line documentation that comes with Transition Networks
FocalPoint™ software for applicable commands and usage.
Use SNMP at an attached terminal or at a remote location to monitor the
media converter by monitoring:
•
Media converter power
•
Line build-out
•
DS3 / T3 / E3 mode
•
Coax link and fiber link status (local and/or remote)
•
Coax loop-back and fiber loop-back status (local only)
•
AIS detected on coax link and fiber link (local and/or remote)
•
Hardware/software mode
Also, use SNMP to enter network commands that:
•
Enable/disable loop-back on the copper link (local only)
•
Enable/disable loop-back on the fiber link (local only)
Installation
-- Continued
Power the Media Converter
The media converter is powered through the Transition
Network’s PointSystem™ chassis.
CCSCF
FL
CL
SDC
PWR
SDF
RX
TX
Fiber
RX
TX
Coax
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
[email protected] -- Click the “Transition Now” link for a live Web chat.
7
Cable Specifications
Coax Cable
DS3 / E3: 75 ohm coax cable with BNC connectors
Fiber Cable
Single mode fiber (recommended):
9 µm
Multimode fiber (recommended):
62.5/125 µm
Multimode fiber (optional):
100/140, 85/140, 50/125 µm
CCSCF3011-100
1300 nm multimode
Fiber Optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity:
min: -30.0 dBm
max: -14.0 dBm
Link Budget:
11.0 dB
CCSCF3013-100
1300 nm multimode
Fiber Optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity:
min: -30.0 dBm
max: -14.0 dBm
Link Budget:
11.0 dB
CCSCF3014-100
1310 nm single mode
Fiber-optic Transmitter Power:
min: -15.0 dBm
max: -8.0 dBm
Fiber-optic Receiver Sensitivity:
min: -31.0 dBm
max: -8.0 dBm
Link Budget:
16.0 dB
CCSCF3015-100
1310 nm single mode
Fiber Optic Transmitter Power:
min: -8.0 dBm
max: -2.0 dBm
Fiber Optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Link Budget:
26.0 dB
CCSCF3016-100
1310 nm single mode
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: 0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Link Budget:
29.0 dB
CCSCF3017-100
1550 nm single mode
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: 0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Link Budget:
29.0 dB
CCSCF3018-100
1300 nm multimode
Fiber-optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber-optic Receiver Sensitivity:
min: -33.5 dBm
max: -14.0 dBm
Link Budget:
14.5 dB
CCSCF3019-100
1310 nm single mode
Fiber-optic Transmitter Power:
min: -15.2 dBm
max: -8.0 dBm
Fiber-optic Receiver Sensitivity:
min: -32.5 dBm
max: -3.0 dBm
Link Budget:
17.3 dB
CCSCF3029-100
1310 nm (TX) / 1550 nm (RX) simplex
CCSCF3029-101
1550 nm (TX) / 1310 nm (RX) simplex
Fiber-optic Transmitter Power:
min: -13.0 dBm
max: -6.0 dBm
Fiber-optic Receiver Sensitivity:
min: -32.0 dBm
max: -3.0 dBm
Link Budget:
19.0 dB
CCSCF3029-102
1310 nm (TX) / 1550 nm (RX) simplex
CCSCF3029-103
1550 nm (TX) / 1310 nm (RX) simplex
Fiber-optic Transmitter Power:
min: -8.0 dBm
max: -3.0 dBm
Fiber-optic Receiver Sensitivity:
min: -33.0 dBm
max: -3.0 dBm
Link Budget:
25.0 dB