beautypg.com

Front panel, Indicator led – Mark Levinson 433 User Manual

Page 13

background image

13

Nº433 Power Amplifier

Front Panel

The numbers in the front-panel illustration shown below corre-
spond with the numbered items that appear below.

1. Indicator LED

Indicates the operating state of the Nº433 and provides diagnostic
information when a fault condition occurs.

* Signal-related faults include significant DC offset at the output due to either DC in the

input signal, or a failed component within the amplifier, OR excessive current demands
due to a short-circuit loudspeaker wire.

Refer to “Extensive Protection” on page 12 for additional infor-
mation about fault conditions. If the amplifier will not power on at
all (even to sleep mode), check the ~ac mains connections or have
an authorized Mark Levinson dealer inspect the internal fuses
(which are not user-serviceable).

power

standby

DUAL MONO AMPLIFIER

Nº432

2

3

1

LED Behavior

Description

Fully lit

Amplifier is powered “on.”

Slowly blinking

Amplifier is in standby.

Dimly lit

Amplifier is in sleep mode.

Not lit

Amplifier is powered “off.”

Rapidly blinking
(on most of the time)

A power-related fault has occurred.

Rapidly blinking
(on half of the time)

A signal-related fault* has occurred.

Rapidly blinking
(off most of the time)

A thermal-related fault has occurred.