OM-4417 Page 12
Continuous Welding
4-5. Duty Cycle
220 625−A
Duty cycle is the percentage of 10
minutes that unit can weld at rated
load without overheating.
Y Exceeding duty cycle can
damage unit and void
warranty.
100% Duty Cycle at 80 Amperes CC/DC
20% Duty Cycle at 145 Amperes CC/DC
% DUTY CYCLE
WELD AMPERES
0
0
10
20
20
30
40
40
50
60
60
70
80
80
90
100
100
120
140
160
2 Minutes Welding
8 Minutes Resting
4-6. Generator Power Curve
220 581
The ac generator power curves
show the generator power available
in amperes at the receptacles.
AMPERES
0
0
10
20
30
40
50
60
70
80
50
100
150
200
250
300
240 Volt
120 Volt
VOL
TS