beautypg.com

Installing the industio cp-114 series board, Connecting the fan-out cable, Installing the industio cp-114 series board -2 – Moxa Technologies CP-114 Series User Manual

Page 12: Connecting the fan-out cable -2, Fan-out cable industio cp-114

background image

2-2

Industio CP-114 User's Manual

!

S2 Data Mode Selection Switch for Port 1/2/3/4:
(Valid if JP5/6 is Left and S1 is ON)

ON*

Set the RS-485 port to Automatic Data Direction Control Mode.

OFF

Set the RS-485 port to By RTS Mode.

!

JP1/2/3/4 Termination Resistor Port 1/2/3/4:
(Valid if JP5/6 is Left and S1 is ON)

Open * Not using Termination Resistor

Short Using

Termination

Resistor


Installing the Industio CP-114 Series Board

The BIOS automatically assigns the IRQ number and I/O addresses for the Industio CP-114 Series

board. Hence, it is a must to have the board plugged first before installing the software driver. After
this, simply install the control board into the PC and then connect the connection cable.

Step 1: Power off the PC.

Warning !

Make sure your system is switched off before you start installing any

board. If you don’t, you may risk damaging your system and the board.


Step 2: Remove the slot cover bracket if present.

Step 3: Plug the Industio CP-114 Series control board firmly into a free 32-bit PCI slot.

Step 4: Fasten the holding screw to fix the control board in place.

Connecting the Fan-out Cable

Step 5: Connect the fan-out cable (DB37 to DB9 x 4).












Step 6:
Power on the PC and the BIOS will automatically set the IRQ and I/O address.

Note !

Each board must occupy one unique IRQ and four 8-byte I/O addresses,
which are assigned automatically by the BIOS.
However, you can select a
free IRQ number manually via the PC’s BIOS setup for the PCI slot, but
normally this method is not available for the I/O address. The possible IRQ
numbers are 2, 3, 4, 5, 7, 10, 11, 12, and 15. The possible I/O addresses are
from 0x0000 to 0xFFFF.


Step 7:
Proceed with the software installation detailed in the next chapter, “Software

Installation”.

Fan-out Cable Industio CP-114

JP1
JP2
JP4
JP3

O
N

1 2 3 4

O
N

1 2 3 4

RS-232

RS-422
RS-485
JP5

RS-232

RS-422
RS-485
JP6

By RTS RS-422

SW2 SW1

AUTO RS-485