To convert the burners
Turn off the main gas supply (if the
appliance has already been in-
stalled) and disconnect the appli-
ance from the main electrial power
supply before proceeding.
The following orifices and needle valves
should be installed into their respective
burners.
Conversion table KM 342
Code
Orifice
size
(Ø mm)
Code
Needle
valve
size
(Ø mm)
Natural gas
Normal
burner
140
1.40
62
0.62
Fast burner
167
1.67
78
0.78
Wok burner
inner
outer
34
190
No. 34
1.90
40
88
0.40
0.88
Propane (LP)
Normal
burner
90
0.90
41
0.41
Fast burner
103
1.03
45
0.45
Wok burner
inner
outer
7
109
No. 7
1.09
25
54
0.25
0.54
Save the orifices and needle valves re-
moved from the appliance for future
use.
Conversion table KM 344
Code Orifice
size
(Ø
mm)
Code
Needle
valve
size
(Ø mm)
Natural gas
Normal
burner
140
1.40
62
0.62
Fast burner
167
1.67
78
0.78
Wok burner
left
inner
outer
34
190
No. 34
1.90
40
88
0.40
0.88
Wok burner
right
inner
outer
34
195
No. 34
1.95
40
88
0.40
0.88
Propane (LP)
Normal
burner
90
0.90
41
0.41
Fast burner
103
1.03
45
0.45
Wok burner
left
inner
outer
7
109
No. 7
1.09
25
54
0.25
0.54
Wok burner
right
inner
outer
7
112
No. 7
1.12
25
54
0.25
0.54
Converting to LP gas
17