How to order, Warranty, Typical wiring diagrams – Murphy Digital Time Meters HD35-CD User Manual

Page 2

background image

1090069

How to Order

Specify:
HD35-CD for 120-250 VAC/CD-Ignition
HD35-DC for 10-40 VDC/24 VAC

Warranty

A two year limited warranty on materials and workmanship
is given with this Murphy product. Details are available on
request and are packed with each unit.

HD35-CD
1.
120-250 VAC; CD ignition power.

2. Terminals 7 and 8 are connected with a factory installed

jumper which initiates a timer immediately after power is
applied between terminals 3 and 4.
To initiate the timer by a remote switch remove the
factory installed jumper between 7 and 8.

3. Connecting terminals 5 and 6 resets the timer to zero.

4. Connect terminal 3 to positive ignition lead.

Connect terminal 4 to negative ignition lead.

5. When replacing battery use only Duracell PX28L

6 VDC Lithium battery. CAUTION: Unless
external power is applied on terminals 3 and 4,
timer will zero when battery is removed.

HD35-DC
1.
10-40 VDC/24 VAC input.

2. Terminals 7 and 8 are connected with a factory installed

jumper which initiates a timer immediately after power is
applied between terminals 3 and 4.
To initiate the timer by a remote switch remove the
factory installed jumper between 7 and 8.

3. Connecting terminals 5 and 6 resets the timer to zero.

4. Connect terminal 3 to power positive.

Connect terminal 4 to power negative.

5. When replacing battery use only Duracell PX28L

6 VDC Lithium Battery. CAUTION: Unless external
power is supplied on terminals 3 and 4, timer
will zero when battery is removed.

6. Display lighting requires 10-40 VDC/24 VAC.

HD35-CD

(2)

5

1

2

3

4

6

7

8

9

Remote

Start

Jumper

(5)

Display

Lighting

(6)

Connect to:

Reset

(3)

CAUTION:

use only to

reset timer

to zero.

(1)

10-40 VDC

or 24 VAC

Input

(4)

Positive and

Negative

Power Source

o r

*

*

HD35-DC

(2)

Connect to:

Reset

5

1

2

3

4

6

7

8

9

Remote

Start

Jumper

(5)

(3)

CAUTION:

use only to

reset timer

to zero.

(1)

120-250 VAC

(4)

Positive or

Negative

Ground CD

Ignition Leads

o r

*

*

Typical Wiring Diagrams

WARNING:

The wiring diagrams below are

shown for clarity only.

Printed in U.S.A.

®

FRANK W.

MFR.

Frank W. Murphy Manufacturer
P.O. Box 470248; Tulsa, Oklahoma 74147; USA
tel. (918) 627-3550 fax (918) 664-6146
e-mail [email protected]

Frank W. Murphy Southern Division
P.O. Box 1819; Rosenberg, Texas 77471; USA
tel. (281) 342-0297 fax (281) 341-6006
e-mail [email protected]

Since 1939

Frank W. Murphy, Ltd.
Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
tel. +44 1722 410055 fax +44 1722 410088 tlx 477088
e-mail [email protected]
Frank W. Murphy Pte., Ltd.
26 Siglap Drive; Republic of Singapore 456153
tel. +65 241-3166 fax +65 241-8382
e-mail [email protected]
Murphek Pty., Ltd.
1620 Hume Highway; Campbellfield, Vic 3061; Australia
tel. +61 3 9358-5555 fax +61 3 9358-5558

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

Murphy de México, S.A. de C.V.
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje
San Luis Potosí, S.L.P.; México 78384
tel. +52-48-206264 fax +52-48-206336
e-mail [email protected]
Murphy Switch of California
P.O. Box 900788; Palmdale, California 93590; USA
tel. (805) 272-4700 fax (805) 947-7570
e-mail [email protected]
Frank W. Murphy France
tel.
+33 1 30 762626 fax +33 1 30 763989

This manual is related to the following products: