How to Order
Specify:
HD35-CD for 120-250 VAC/CD-Ignition
HD35-DC for 10-40 VDC/24 VAC
Warranty
A two year limited warranty on materials and workmanship
is given with this Murphy product. Details are available on
request and are packed with each unit.
HD35-CD
1. 120-250 VAC; CD ignition power.
2. Terminals 7 and 8 are connected with a factory installed
jumper which initiates a timer immediately after power is
applied between terminals 3 and 4.
To initiate the timer by a remote switch remove the
factory installed jumper between 7 and 8.
3. Connecting terminals 5 and 6 resets the timer to zero.
4. Connect terminal 3 to positive ignition lead.
Connect terminal 4 to negative ignition lead.
5. When replacing battery use only Duracell PX28L
6 VDC Lithium battery. CAUTION: Unless
external power is applied on terminals 3 and 4,
timer will zero when battery is removed.
HD35-DC
1. 10-40 VDC/24 VAC input.
2. Terminals 7 and 8 are connected with a factory installed
jumper which initiates a timer immediately after power is
applied between terminals 3 and 4.
To initiate the timer by a remote switch remove the
factory installed jumper between 7 and 8.
3. Connecting terminals 5 and 6 resets the timer to zero.
4. Connect terminal 3 to power positive.
Connect terminal 4 to power negative.
5. When replacing battery use only Duracell PX28L
6 VDC Lithium Battery. CAUTION: Unless external
power is supplied on terminals 3 and 4, timer
will zero when battery is removed.
6. Display lighting requires 10-40 VDC/24 VAC.
HD35-CD
(2)
5
1
2
3
4
6
7
8
9
Remote
Start
Jumper
(5)
Display
Lighting
(6)
Connect to:
Reset
(3)
CAUTION:
use only to
reset timer
to zero.
(1)
10-40 VDC
or 24 VAC
Input
(4)
Positive and
Negative
Power Source
o r
*
*
HD35-DC
(2)
Connect to:
Reset
5
1
2
3
4
6
7
8
9
Remote
Start
Jumper
(5)
(3)
CAUTION:
use only to
reset timer
to zero.
(1)
120-250 VAC
(4)
Positive or
Negative
Ground CD
Ignition Leads
o r
*
*
Typical Wiring Diagrams
WARNING:
The wiring diagrams below are
shown for clarity only.
Printed in U.S.A.
®
FRANK W.
MFR.
■ Frank W. Murphy Manufacturer
P.O. Box 470248; Tulsa, Oklahoma 74147; USA
tel. (918) 627-3550 fax (918) 664-6146
e-mail [email protected]
■ Frank W. Murphy Southern Division
P.O. Box 1819; Rosenberg, Texas 77471; USA
tel. (281) 342-0297 fax (281) 341-6006
e-mail [email protected]
Since 1939
■ Frank W. Murphy, Ltd.
Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
tel. +44 1722 410055 fax +44 1722 410088 tlx 477088
e-mail [email protected]
■ Frank W. Murphy Pte., Ltd.
26 Siglap Drive; Republic of Singapore 456153
tel. +65 241-3166 fax +65 241-8382
e-mail [email protected]
■ Murphek Pty., Ltd.
1620 Hume Highway; Campbellfield, Vic 3061; Australia
tel. +61 3 9358-5555 fax +61 3 9358-5558
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
■ Murphy de México, S.A. de C.V.
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje
San Luis Potosí, S.L.P.; México 78384
tel. +52-48-206264 fax +52-48-206336
e-mail [email protected]
■ Murphy Switch of California
P.O. Box 900788; Palmdale, California 93590; USA
tel. (805) 272-4700 fax (805) 947-7570
e-mail [email protected]
■ Frank W. Murphy France
tel. +33 1 30 762626 fax +33 1 30 763989