10 Re-fit dust canister into cleaner and push to

lock into position. Then re-fit front cover.

Safety cut-out

If the cleaner overheats a motor protection

thermostat will automatically switch the motor
off. If this happens, switch the cleaner off,
unplug from the power supply and leave
the cleaner to cool for at least 30
minutes.
Check the airways for blockages,
empty dust canister and clean the filters before
restarting.

Cleaning the filters

To maintain suction the pleated filter

must be shaken clean each time the dust
canister is emptied.
Failure to clean the filter
will reduce suction and could damage the
motor if used for a prolonged period. This may
invalidate the guarantee. If the filters become
damaged they must be replaced.

Pleated filter

This must be shaken clean at every

emptying to maintain suction. To thoroughly
clean it wash it regularly.

To remove it from the dust canister lid turn

the filter

1/

4

turn anti-clockwise. H Wash in

warm water (no detergent) and allow to air dry
before refitting. The spare pleated filter allows
one filter to be washed and dried whilst the
other is in use.

Motor protection filter

I

The motor protection filter Ò is located

underneath the dust canister
1 Remove the dust canister.
2 Lift out the filter and shake over a dustbin.

The filter may also be washed in water (no

detergents) but must be totally dry before re-
fitting.
3 Replace the filter

Exhaust filter

I

The exhaust filter is located below the dust

canister compartment.
1 Remove the front cover.
2 Remove the exhaust filter Ú by pulling

forward at the top and lift it away.

3 Take the filter out of the cage and shake

vigorously over a dustbin. The filter may also
be washed in warm water. Do not use
detergents. The filter must be completely dry
before re-fitting. Allow filters to air dry
naturally.

4 Replace the filter and front cover.

Changing the belt

If the brush bar stops rotating it is likely that

the drive belt has snapped (usually because the
brush has been stalled). A spare belt is
supplied. Replacement belts can also be
obtained from Morphy Richards.

Accessing the floor nozzle

J

1 Disconnect the cleaner from the mains

supply.

2 Put switch to off position.
3 Remove front cover and dust canister.
4 Press the handle release pedal and place

the cleaner face down, in a flat position on a
soft surface (eg carpet).

6

I

H

Т