beautypg.com

Multiquip MQ Power Whisperwatt Series DCA-36SPX User Manual

Page 30

background image

PAGE 30 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV. #1 (04/14/10)

UOV Terminal Output Voltages

240/120V output voltages can be obtained using the

Output

Terminal Lugs..

The voltage regulator (VR) allows the user to increase or
decrease the selected voltage.

1Ø 240 Output Terminal Lug Voltages

1. Connect the load wires to the

Output Terminal Lugs as

shown in (Figure 17)

Figure 17. Output Terminal Lugs

240 Single Phase Connections

2. Turn the voltage regulator knob (Figure 18) clockwise to

increase voltage output, turn counterclockwise to
decrease voltage output.

Figure 18. Voltage Regulator Knob (139V/240V)

2. Turn the voltage regulator knob (Figure 18) clockwise to

increase voltage output, turn counterclockwise to
decrease voltage output.

How to Read the Output Terminal Gauges.

The gauges on the control panel are provided to help
observe how much power is being supplied at the

Output

terminals lugs.

Figure 16. AC Ammeter

(Amp reading on U lug)

Figure 15. AC Ammeter

Change-Over Switch

Reading Amperage

To determine the amperage at a terminal lug, set the
AC Ammeter Change-Over Switch to the appropriate
setting (Figure 15) to activate the

AC Ammeter Gauge

(Figure 16) and read the available amperage at the terminal
lug.

For example, to measure the amperage at the U
terminal lug, set the

AC Ammeter Change-Over Switch to

U and read the AC Ammeter Gauge.

The

ammeter gauge will only

show a reading when the

Output

Terminal Lugs are connected
to a load and in use.

NOTE

DCA-36SPX — GAUGE READING/ TERMINAL PANEL CONNECTIONS

1Ø 120 Output Terminal Lug Voltages

1. Connect the load wires to the

Output Terminal Lugs as

shown in (Figure 19)

Figure 19. Output Terminal Lugs

120 Single Phase Connections

This manual is related to the following products: