beautypg.com

Milwaukee 5223 User Manual

Page 4

background image

6

7

FUNCTIONAL DESCRIPTION

1

2

3

4

5

6

7

Cat. No. 5211

3"

1

2

3

6

7

4

8

Cat. No. 5223

5"

1

2

4

3

5

6

7

Cat. No. 5243

6"

1. Trigger

2. Motor

housing

3. Spindle housing

(insulated handle)

4. Guard assembly clamp

5. Faceplate

6. Guard

assembly

7. Tool

rest

8. Spindle

Nut

No Load

RPM

14500

7000
5700

Volts

AC/DC

120
120
120

Cat.

No.

5211
5223
5243

Specifi cations

Grounding Req. or

Double Insulated

Double Insulated
Double Insulated

Grounding Required

Arbor Size

Diameter,

Threads

3/8" - 24
5/8" - 11
5/8" - 11

Wheel Size
Thickness,

Diameter

1/2" x 3"

1" x 5"
1" x 6"

Mexican Safety
Standards

Double Insulated

Symbology

Volts Alternating Current/
Direct Current

No Load Revolutions per
Minute (RPM)

Amps

Underwriters Laboratories, Inc.,
United States and Canada

The grounding prong in the plug is connected
through the green wire inside the cord to
the grounding system in the tool. The green
wire in the cord must be the only wire con-
nected to the tool's grounding system and
must never be attached to an electrically
“live” terminal.

Your tool must be plugged into an appropri-
ate outlet, properly installed and grounded in
accordance with all codes and ordinances.
The plug and outlet should look like those
in Figure A.

Double Insulated Tools:
Tools with Two Prong Plugs

Tools marked “Double Insulated” do not
require grounding. They have a special
double insulation system which satisfies
OSHA requirements and complies with
the applicable standards of Underwriters
Laboratories, Inc., the Canadian Standard
Association and the National Electrical
Code. Double Insulated tools may be used
in either of the 120 volt outlets shown in
Figures B and C.

Grounded Tools:
Tools with Three Prong Plugs

Tools marked “Grounding Required” have a
three wire cord and three prong grounding
plug. The plug must be connected to a prop-
erly grounded outlet (See Figure A). If the
tool should electrically malfunction or break
down, grounding provides a low resistance
path to carry electricity away from the user,
reducing the risk of electric shock.

Fig. B

Fig. C

Fig. A

Improperly connecting the grounding
wire can result in the risk of electric
shock. Check with a qualifi ed electri-
cian if you are in doubt as to whether
the outlet is properly grounded. Do
not modify the plug provided with
the tool. Never remove the grounding
prong from the plug. Do not use the
tool if the cord or plug is damaged.
If damaged, have it repaired by a
MILWAUKEE
service facility before
use. If the plug will not fi t the outlet,
have a proper outlet installed by a
qualifi ed electrician.

GROUNDING

WARNING

This manual is related to the following products: