Left – M-AUDIO MICROTRACK 24/96 User Manual
Page 6
MicroTrack 24/96 User Guide
5
English
Left
15.
Menu Button: Toggles between the Main Menu and record screen, or acts as an exit button when in a sub menu.
16. Hold Switch: When active, all buttons on the MicroTrack 24/96 will be disabled. If you attempt to operate the MicroTrack 24/96
while the Hold switch is on, “HOLD switch on” will be shown on the LCD display.
17.
L/M/H Switch: Sets the operating mode of the 1⁄4” TRS and 1/8” inputs. Use the ‘L’ position for line-level devices. The ‘M’ position
should be used when recording from microphones. The ‘H’ position uses a higher gain stage on the 1⁄4” TRS inputs, which can
help when recording quiet signals or using microphones with low output levels. The ‘H’ position does not boost the input gain of
the 1/8” input.
18.
Ph Pwr Switch: Switches on the phantom power for the 1⁄4” TRS inputs. When active, a “Ph” icon will be shown on the LCD display.
Phantom power should only be used with condenser microphones.
IMPORTANT: Phantom power should be disengaged when connecting or disconnecting microphones to prevent possible damage
to the microphone’s internal electronics.
3 - Hardware Controls and Indicators