OM-1589 Page 13
3-4.
Rear Panel Connections
Ref. 800 689
1
Rating Label Location
2
Coolant Supply Hose
Route supply hose and connect to
rear of Water To Gun fitting in
feeder.
3
Weld Cable
If using conventional welding power
source, route through reed relay in
feeder. Connect to power block.
4
Coolant Return Hose
Route return hose and connect to
rear of Weld/Water From Gun fitting
or optional flow switch in feeder.
5
Gas Hose
6
14-Pin Plug
Tools Needed:
9/16, 5/8, 11/16 in
6
5
2
3
4
1
3-5.
14-Pin Plug Information
Pin*
Pin Information
A
24 volts ac with respect to socket G.
A
J
B
Contact closure to A completes 24 volts ac contactor control circuit.
A
J
B
K
I
G
Circuit common for 24 volts AC circuit.
B
K
I
C
L
N
H
D
Remote control circuit common.
C
L
N
H
D
M
G
E
F
E
0 to +10 volts dc input command signal from remote control with respect to socket D.
D
M
G
E
F
H
Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.
F
Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.
M
CC/CV Select (+24 V = CV)
N
Inductance (0-10 V)
*The remaining pins are not used.