GAS CONNECTIONS

Your cooker is delivered adjusted for the kind of
gas stated on the rating plate

If the appliance is supplied with natural gas and
the pressure for natural gas is 20mbar. The
following methods of connection to the gas
supply must be used:

Right Hand Connection (from front)
Ensure that the rubber hose is not in contact
with any part of the hatched area shown in the
diagram and that the loop of the hose when
connected is not in contact with the floor when
the appliance is in position.

Left Hand Connection (from front)
Ensure that the rubber hose is not in contact
with any part of the hatched area shown in the
diagram and the hose is retained in the clamp
provided, it will be necessary to fit the maximum
length hose when using this method.

Fixing and use of the 2 clips provided with
the cooker
The enclosed gas hose fixing clips must be fixed
to the back of the cooker, dependant on the
position of the supply bayonet connector (see
fig.).

When selecting the most suitable position for the
clips, please ensure that the gas hose cannot
come into contact with any part of the “Hot” zone
when pushing the cooker into its final position.

Finally, secure the hose into the clips.

Rigid Connection
Where it is not possible to make the connection
using a rubber hose, a rigid pipe work
connection must be used.

Recommendations when using an appliance
flexible connector are as follows:
- For NATURAL the gas installation pipes to the
termination point shall comply with:
Specification for installation of low-pressure
gas pipe work of up to 20mm (R1) in
domestic premises (2nd family gas) – BS
6891;

power cord

BACK OF THE COOKER

connection

of flexible

hose

clamps

clamps

connection

of flexible

hose

power cord

BACK OF THE COOKER

Clip Position

Options

clip

Connection shall be by means of an appliance
flexible connector for use with a self-sealing
plug-in device, complying with:
Flexible hoses, end fittings and sockets for
gas burning appliances – BS 669;