beautypg.com

Instructions for the installer – Moffat GSC 5061 User Manual

Page 18

background image

18

INSTRUCTIONS FOR THE INSTALLER

SAFETY ADVICE

• Before installation ensure that the local

distribution conditions (gas type and
pressure) and the pre-setting of the
appliance are consistent.

• This appliance must be installed only in a

room with good ventilation.

• This appliance must not connected to a flu.

It has to be installed and connected in
accordance with the rules in force. Special
attention should be paid to the applicable
disposal concerning ventilation.

• The adjacent furniture panels have to be

heat proof or protected by such material.

• The adjusting conditions of this appliance

are mentioned on the rating plate.

Connection to gas supply.
Check that the gas flow and the diameter of the
supply pipe is sufficient to supply all the
appliances of the installation.
• Check that all connections are tight.
• Install an accessible and visible gas tap to

isolate the appliance.

ELECTRIC CONNECTION

Any electrical work required to install

this cooker should be carried out by a
qualified electrician or competent person, in
accordance with the current regulations.

This cooker must be earthed.

This cooker is designed to be connected to a
240V 50Hz AC electrical supply.
Before switching on, make sure the electricity
supply voltage is the same as that indicated on
the rating plate.

Important

We decline any responsibility in case of

accidents due to no grounding or wrong
grounding.

Important

If the supply cord is damaged it must be

replaced by the manufacturer or its
service agent or a similarly qualified
person in order to avoid a hazard.

-

Installation of flues and ventilation for
gas appliances of rated input not
exceeding 60 kW (1

st

, 2

nd

and 3

rd

family

gases) – Part 2 Specification for
installation of ventilation for gas
appliances – BS 5440;

-

Gas burning appliances – Part 3
Domestic cooking appliances burning
gas – BS 5386;

-

Specification for installation of low
pressure gas pipe work of up to 20mm
(R1) in domestic premises (2

nd

family

gas) – BS 6891;

-

Pipe threads for tubes and fittings where
pressure-tight joints are made on the
threads (metric dimensions) – BS 21:
1985;

-

Flexible hoses, end fittings and sockets
for gas burning appliances – BS 669;

Installation of domestic gas cooking
appliances (1

st

, 2

nd

and 3

rd

family gases) – BS

6172: 1990;