Dca-220ssj/ssju — diagnostic display, 1800 rpm – Multiquip MQ Power Whisperwatt 50 Hz Generator DCA-220SSJ User Manual
Page 25
DCA-220SSJ/SSJU— OPERATION AND PARTS MANUAL — REV. #1 (01/06/09) — PAGE 25
1
2.
The main menu will pop up on the display. Use the “Arrow
Buttons” to scroll through the menu until the “Engine
Configuration” menu item has been highlighted.
3.
Once the “Engine Configuration” menu item has been
highlighted touch the “Enter Button” to view the engine
configuration data.
4.
Use the “Arrow Buttons” to scroll through the engine
configuration data.
5.
Touch the “Menu Button” to return to the main menu.
6.
Touch the “Menu Button” to exit the Main menu and
return to the engine parameter display.
FAULTS AND WARNINGS
Auxiliary Gage Fault
1.
During normal operation the single or four parameter
screen will be displayed.
2.
The PVA Series of auxiliary gages can be attached to
the PowerView. These auxiliary gages communicate with
the Modbus master PowerView via a daisy-chained RS-
485 port. If at any time during system initialization or
normal operation an auxiliary gage should fail, the single
or four parameter screen will be replaced with the “MLink
Gage Fault” message.
3.
To acknowledge and “Hide” the fault and return to the
single or four parameter display, touch the “Enter Button”.
4.
The display will return to the single or four parameter
screen.
GO TO 1-UP DISPLAY
STORED CODES
ADJUST BACKLIGHT
SETUP 1-UP DISPLAY
SETUP-4-UP DISPLAY
SELECT UNITS
ENGINE CONFG
GO TO 1-UP DISPLAY
STORED CODES
ADJUST BACKLIGHT
SETUP 1-UP DISPLAY
SETUP-4-UP DISPLAY
SELECT UNITS
ENGINE CONFG
ENGINE SPEED PT 1
1800 RPM
MORE
ENGINE SPEED PT 1
1800 RPM
MORE
COOL
1800 RPM
0
1500
3000
TEMP
ENG RPM
98%
14.2
57 PSI
1000 RPM
LOAD RPM
BATT VOLT
ENG RPM
OIL PRES
ENGINE OIL PRESSURE
GAGE NOT RESPONDING
1 of x
HIDE
ENGINE OIL PRESSURE
GAGE NOT RESPONDING
1 of x
HIDE
COOL
1800 RPM
0
1500
3000
TEMP!
ENG RPM
!
98%
14.2
!
57 PSI
1000 RPM
LOAD RPM
BATT VOLT
ENG RPM
OIL PRES
!
DCA-220SSJ/SSJU — DIAGNOSTIC DISPLAY