Dial stored telephone number command, Echo command mode characters command, Echo online data characters command – Multi-Tech Systems MT5634MSV User Manual
Page 40: Version, Hangup command, Hook control command, Information request command, On-hook/off-hook, Rom checksum, Messagesaver user guide
MessageSaver User Guide
32
V
Switch to speakerphone mode and dial the following num-
ber. Use ATH command to hang up.
W
Wait for a new dial tone before continuing to dial. (X2, X4,
X5
, X6, or X7 must be selected.)
,
Pause during dialing for time set in register S8.
;
Return to command mode after dialing. (Place at end of
dial string.)
!
Hook flash. Causes the modem to go on-hook for one-half
second, then off-hook again.
@
Wait for quiet answer. Causes modem to wait for a ring-
back, then 5 seconds of silence, before processing next part
of command. If silence is not detected, the modem returns
a NO ANSWER code.
^
Disable data calling tone transmission.
$
Detect AT&T call card “bong” tone. The character should
follow the phone number and precede the user’s call card
number: ATDT1028806127853500$123456789
Command:
DS=
y Dial Stored Telephone Number
Values:
y = 0–3
Default:
none
Description:
Dial a number previously stored in directory number y by the
&Zy=x
command. Example: ATDS=3.
Command:
E
n
Echo Command Mode Characters
Values:
n = 0 or 1
Default:
1
Description:
E0
Do not echo keyboard input to the terminal.
E1
Do echo keyboard input to the terminal.
Command:
F
n
Echo Online Data Characters
Values:
n = 1
Default:
1
Description:
F0
Enable online data character echo. (Not supported.)
F1
Disable online data character echo (included for backward
compatibility with some software).
Command:
H
n
Hook Control
Values:
n = 0 or 1
Default:
0
Description:
H0
Go on-hook (hang up).
H1
Go off-hook (make the phone line busy).
Command:
I
n
Information Request
Values:
n = 0–5, 9, 11
Default:
None
Description:
I0
Display default speed and controller firmware version.
I1
Calculate and display ROM checksum (e.g., 12AB).
I2
Check ROM and verify the checksum, displaying OK or ERROR.
I3
Display default speed and controller firmware version.
I4
Display firmware version for data pump (e.g., 94).