OBSERVED PROBLEM

ODS/pilot lights, but flame
goes out when control knob is
released.

Burner does not light after ODS/
pilot is lit.

Burner backfires during com-
bustion.

Slight smoke or odor during
initial operation.

Logs appear to smoke after ini-
tial operation.

Heater produces a whistling
noise when burner is lit.

No gas to pilot.

POSSIBLE CAUSE

1. Control knob not fully pressed in.
2. Control knob not pressed in long enough.

3. Manual shutoff valve not fully open.
4. Thermocouple connection loose at control

valve.

5. Pilot flame not touching thermocouple, which

allows thermocouple to cool, causing pilot
flame to go out. This problem could be caused
by either low gas pressure, or a dirty or
partially clogged ODS/pilot.

6. Thermocouple damaged.
7. Control valve damaged.

1. Burner orifice is clogged.
2. Burner orifice diameter is too small.
3. Inlet gas pressure is too low.

1. Manifold pressure is too low.
2. Burner orifice is clogged.

1. Burner orifice is clogged or damaged.
2. Burner is damaged.
3. Gas regulator defective.

1. Vapors from paint or curing process of logs.

2. Vapors or smoke continue after heater has

run with damper or window open for several
hours.

1. Turning control knob to HIGH position when

burner is cold.

2. Air in gas line.

3. Dirty or partially clogged burner orifices.

1. LP-regulator shut down due to inlet pressure

too high.

REMEDY

1. Press in control knob fully.
2. After ODS/pilot lights, keep control

knob pressed in for 30 seconds.

3. Fully open manual shutoff valve.
4. Hand tighten thermocouple connection

until snug, then tighten 1/4 turn more.

5a. Contact local gas company.
5b. Clean pilot with vacuum cleaner.

6. Replace thermocouple.
7. Replace control valve.

1. Clean orifice.
2. Replace burner orifice.
3. Contact qualified service person.

1. Contact local gas company.
2. Clean burner or replace burner orifice.

1. Clean burner or replace burner orifice.
2. Replace burner.
3. Replace gas regulator.

1. Problem will stop after a few hours

of operation. Run the heater with the
damper open if you have one, or open a
window for the first few hours.

2. Log heater is intended to be smokeless.

Turn OFF heater and call qualified
service person.

1. Turn control knob to LOW position and

let warm up for a minute.

2. Operate burner until air is removed from

line. Have gas line checked by local
gas company.

3. Clean burner or replace burner orifice.

1. Verify LP tank regulator is installed and

set at 11" to 13" w.c.

2. Replace regulator on heater.

TROUBLESHOOTING

If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and
the heater may backfi re when lit. If the gas quality or pressure is low, contact your local
gas supplier immediately.