ELECTRICAL WIRING

The milli-volt valve is a self-powered combination gas control THAT DOES NOT REQUIRE 110 VAC TO
OPERATE.

CONNECTING OPTIONAL WALL SWITCH

1. Use 18 awg, two-wire cable, 15 feet maximum length.
2. At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to

TP/TH and one wire to TH, or connect the wall switch/thermostat to the two male (0.25") terminals on the left side of
the unit. The color of the wires does not matter.

Figure 17 - Wiring Diagram

Optional Wall

Switch or Remote

Receiver

Switch

On/Off
Switch

On/Off
Switch

Wall

Switch

ODS

Pilot

Valve

TH = 3

TP = 1

TP/TH = 2

ODS

Pilot

Spade

Terminal

Label all wires prior to disconnection
when servicing controls. Wiring
errors can cause improper and
dangerous operation. Verify proper
operation after servicing.