Clearances, Height requirements, Warning – Monessen Hearth DFS36NVC User Manual

Page 14

background image

14

71D0532

9"

Minimum

9"

Minimum

42" Minimum

12"

10"

8"

6"

2

1

/

2

"

12"

16"

19"

21"

23"

Combustible material
can contact top of
fi replace.

N o n - c o m b u s t i b l e
material only if needed to
cover optional radiant top

panel above canopy.

CLEARANCES

AND

HEIGHT REQUIREMENTS

Sidewall and ceiling clearances:

The clear-

ance from the inside of the appliance to any com-
bustible adjacent wall should no be less than 9".
See Figure 7.

Ceiling clearance:

The ceiling must be at least

42" from the top of the firebox opening. See Figure
7.

Back wall clearance:

The appliance may be

placed against a combustible back wall.

Floor clearance:

The fireplace may not be

installed onto any combustible flooring material,
such as carpeting, vinyl or tile without the hearth
or a minimum 22 GA (0.030") metal or a minimum
1/2" wooden base covering the entire width and
depth of the base. Combustible material must be
installed at least one inch away from the front face
of the unit.

Mantel clearances:

The canopy supplied with

the unit must be installed. If a combustible mantel
is installed. It must meet the clearance requirements
shown in Figure 8.

Figure 7 - Sidewall and Ceiling Clearances

W

ARNING

Figure 8A - Minimum Mantel Clearances

Figure 8B - Mantel Heights

The dimensions shown in Figures 7 and 8 and defi ned in the fi replace manufacturer's
instructions are minimum clearances
to maintain when installing this heater. Left and
right clearances are determined when facing the front of the heater.

Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fi re hazard.

For Wide Brass Canopy. See pg. 35