beautypg.com

3 dip switch configuration, Figure 4 – dip switch settings, Figure 5 -- dip switches and pcb revision examples – MRV Communications EM316-2SFP User Manual

Page 14: Dip switch settings

background image

EM316-2SFP User Guide

P/N 1259003-001 Rev C3

5

3.3 DIP Switch Configuration


The EM316-2SFP factory default configuration is designed to operate in the most common
applications.

Network Management = Enabled
LIN = Disabled
Loopback = Disabled


The default configuration optimizes the EM316-2SFP module in most applications. Network
management configuration does not override hardware DIP switch settings. These settings can
only be changed using the DIP switches (SW1) on the EM316-2SFP module, regardless of
previous card installations and network management configuration.


Refer to network management sections of this document, the Command Line Interface User Guide,
or MegaVision documentation for additional information about EM316-2SFP management.

DIP Switch Settings

SW #

Function

ON

OFF

Default

1 Loopback

Disable

Enable

ON

2 NMS

Disable

Enable

OFF

3 LIN

Disable

Enable

ON

4 RESERVED

Must remain ON

Figure 4 – DIP switch settings


EM316-2SFP Default DIP Switch (SW1) Positions

PCB rev 003R

PCB rev 004R

PCB rev 006R

Figure 5 -- DIP switches and PCB revision examples


The DIP switch components and labeling has changed between PCB revisions. Figure 5 above
illustrates some DIP switch examples by PCB revision. Note that the ON position in these
revisions, as labeled on the DIP switch component, represents DISABLE for the feature as

described in Figure 4. Refer to the pictures above for proper DIP switch polarity on the PCB
revisions cited.