OperatiOn

This section is intended to assist the operator with the initial

start-up of the portable generator. It is extremely important

that this section be read carefully before attempting to use

the generators in the field.

Before starting the engine

1. Be sure to disconnect all electrical loads from the

generators prior to starting the engine.

2.

NeveR start the engine with the main circuit breaker

in the

ON position. Always place this circuit breaker

(Figure 9) in the

OFF position before starting.

Figure 9. Main Circuit Breaker (OFF)

starting the engine

1. Place the engine fuel valve lever (Figure 10) to the

ON

position.

Figure 10. Engine Fuel Valve Lever (ON)

2. Place the choke lever (Figure 11) in the

clOsed

position if starting a cold engine.

Figure 11. Choke Lever

3. Place the choke lever (Figure 11) in the

OpeN position

if starting a warm engine or the temperature is warm.

4. Place the generator's operation switch (Figure 12) in

the

ON position.

Figure 12. Operation Switch (ON)

5. Grasp the starter grip (Figure 13) and slowly pull it out.

The resistance becomes the hardest at a certain

position, corresponding to the compression point. Pull

the starter grip briskly and smoothly for starting.

Figure 13. Starter Grip

6. If the engine has started, slowly return the choke lever

(Figure 11) to the

OpeN position. If the engine has not

started repeat steps 1 through 5.

NOTICE

dO NOT pull the starter rope all the way to the end.
dO NOT release the starter rope after pulling. Allow it

to rewind as soon as possible..