OperatiOn/sHutdOwn
13. Read voltmeter on front panel of generator (Figure 22)
and verify that 240 VAC is displayed. Using an external
voltmeter as shown in Figure 20, verify that 240 VAC
is present at the 240V twist-lock receptacle.
Figure 22. 240V Receptacle
14. Connecting of loads (power tools, lighting ect.) to the
generator receptacles can now be done.
stopping the engine (Normal shutdown)
1. Place main circuit breaker (Figure 23) in the
OFF
position.
Figure 23. Main Circuit Breaker (OFF)
NOTICE
When using a combination of dual receptacles, total
load should not exceed the rated capacity of the
generator.
2. Place GFCI circuit breaker (Figure 24) in the
OFF
positing.
Figure 24. GFCI Circuit Breaker (OFF)
3. Place idle control switch (Figure 25) in the
OFF position.
Figure 25. Idle Control switch (OFF)
4. Let engine run at idle with no load for 2-3 minutes.
5. To shut-down the engine, place the generator's
operation switch (Figure 26) in the
OFF position).
Figure 26. Operation Switch (OFF)
6. Place engine fuel valve lever (Figure 27) in the
OFF
position.
Figure 27. Engine Fuel Valve Lever (OFF)
7. Remove all loads from the generator.
emergency shutdown
8. Place operation switch (Figure 26) in the
OFF position