Components (generator) – Multiquip pOrtable generatOr (HOnda gX340 gasOline engine) gaC6HZ User Manual
Page 17

gaC-6HZ 60 HZ geNeRaTOR • OpeRaTiON aNd paRTs maNual — Rev. #1 (03/31/10) — page 17
COMpOnents (generatOr)
120V
240V
OFF
240
V
120
BOUTON DE
DEMARRAGE
START
BUTTON
AC VOLTMETER
VOLTOMETRE CA
ON
OFF
ON
OFF
MARCHE
MARCHE
INTERRUPTEUR
DE OPERATION
OPERATION
SWITCH
CONTROL
DE RALENTI
IDLE
CONTROL
ARRET
ARRET
AC CIRCUIT
BREAKER
(for main)
INTERRUPTEUR DE
COURANT PRINCIPAL
GAC-6HZ
POWERED by
Honda Engines
211052
GFCI CIRCUIT
BREAKER
INTERRUPTEUR DE
COURANT
1
4
5
3
2
6
7
8
9
10
11
Figure 3. Generator Components
1.
main Breaker – This 2-pole circuit breaker (120/240V,
21 amps) protects the generator from short circuiting
or overloading. When starting the generator always
have the circuit breaker placed in the "
OFF" position.
2.
gFCi Breaker – This single pole circuit breaker (120V,
15 amps) protects the GFCI receptacle. When starting
the generator always have the circuit breaker placed
in the "
OFF" position.
3.
idle Control switch – The generator is provided with
an automatic idle control device for noise suppression
and reduced fuel consumption.
The automatic idle control automatically engages under
a no-load condition. With the automatic idle control
switched “
ON”, the engine revolutions will automatically
drop to about 2600 rpm (low-speed operation) within
3 seconds after the load stops. When the operation is
resumed, the engine speed is automatically increased
to about 3600 rpm (high-speed operation) as soon as
the load is connected.
4.
Operation switch – Place switch in the "ON" position
(up) for normal operation. To turn-off the generator,
place the operation switch in the "
OFF" position (down).
5.
aC-voltmeter – This voltmeter indicates (with a
mark) the rated 60 Hz (single-phase) output voltage.
In addition the voltmeter can also be used as a
diagnostic tool. If the voltmeter indicator (needle) is
below the rated voltage, engine problems may exist
(low/high RPM's). To prevent damage to the generator
or power tools turn the generator
OFF and consult your
authorized Multiquip service dealer.
6.
start Button – Press this pushbutton switch to start
the generator.
7.
gFCi duplex Receptacle – NEMA 5-15R, GFCI
receptacle will provide 120V, 15 amps.
8.
120v Output Receptacle – NEMA L5-30R twist-lock
receptacle will provide 120V, 30 amps, 60 Hz.
9.
240v Output Receptacle – NEMA L6-20R twist-lock
receptacle will provide 240V, 20 amps, 60 Hz.
10.
ground – This ground connection point should be
connect to a good earth ground (ground rod).
11.
Battery – This generator is equipped with a 12 VDC
battery. Replace with only recommended type battery.