PDxx01

RS-232C Control Specification Page: 9 / 49

Document Version [1.0]

Company Restricted

5-4.

VOLUME Gain Data

Function
The external control equipment changes the VOLUME gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER SOUND Gain Flag

05H

DATA01: VOLUME Gain Flag

01H

DATA02: VOLUME Gain

00H: Step0

:

0AH: Step10 (Default)

:

2AH:

Step42

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER SOUND Gain Flag

05H

DATA01: VOLUME Gain Flag

01H

5-5.

AUDIO Mute ON

Function
The external control equipment switches on AUDIO Mute of the plasma monitor.

Transmission Data

9FH 80H 60H 3EH 00H CKS

ACK

3FH 60H 80H 3EH 00H CKS

5-6.

AUDIO Mute OFF

Function
The external control equipment switches off AUDIO Mute of the plasma monitor.

Transmission Data

9FH 80H 60H 3FH 00H CKS

ACK

3FH 60H 80H 3FH 00H CKS