RS-232C Control Specification Page: 11 / 49

Document Version [1.0]

Company Restricted

5-9.

SHARPNESS Gain Data

Function
The external control equipment changes the SHARPNESS gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: SHARPNESS Gain Flag

06H

DATA02: SHARPNESS Gain

F0H: -16

:

FFH:

-01

00H:

0

01H:

+01

:

10H:

+16

Only when a RGB signal is connected

DATA02 : SHARPNESS Gain

01H: 1

02H:

2

03H:

3

04H:

4

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: SHARPNESS Gain Flag

06H

5-10.

COLOR Gain Data

Function
The external control equipment changes the COLOR gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: COLOR Gain Flag

04H

DATA02: COLOR Gain

E0H: -32

:

FFH:

-01

00H:

0

01H:

+01

:

20H:

+32

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: COLOR Gain Flag

04H